A fix is available
APAR status
Closed as new function.
Error description
Added support to VMEVENT Enhancements [VM66679]: With the PTF for APAR VM66679, z/VM 7.3 provides the new and changed VMEVENT data for use in operations automation, resource monitoring, and auditing. . This change will add support in Operations Manager to use the new and changed VMEVENT data for below classes and types. . Class 0 type 28 new reconnect event - Reconnect events include logon-by and terminal information as part of the event message. . Class 0 type 29 new disconnect event - new VMEVENT type added with the PTF for APAR VM66679. . Class 0 type 0 LOGON event - Additional logon-by and terminal information is added to the existing logon event. . Class 0 type 3 LOGOFF timeout started event - provide a full-precision (32-bit) timeout interval for the logoff timeout service. . class 1 type 3 LOGOFF timeout in progress event - provide a full-precision (32-bit) timeout interval for the logoff timeout service. . For more information on new event types, refer to the VM Event System Service (*VMEVENT) described in the CP Programming Services Documentation (SC24-6272-73). .
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of IBM Operations Manager for z/VM * **************************************************************** * PROBLEM DESCRIPTION: Added support to VMEVENT Enhancements * * for APAR VM66679. * **************************************************************** * RECOMMENDATION: Apply the PTF * **************************************************************** Added support to VMEVENT Enhancements (VM66679): With the PTF for APAR VM66679, z/VM 7.3 provides the new and changed VMEVENT data for use in operations automation, resource monitoring, and auditing. This change will add support in Operations Manager to use the new and changed VMEVENT data for below classes and types. Class 0 type 28 new reconnect event: Reconnect events include logon-by and terminal information as part of the event message. Class 0 type 29 new disconnect event: new VMEVENT type added with the PTF for APAR VM66679. Class 0 type 0 LOGON event: Additional logon-by and terminal information is added to the existing logon event. Class 0 type 3 LOGOFF timeout started event: provide a full-precision (32-bit) timeout interval for the logoff timeout service. class 1 type 3 LOGOFF timeout in progress event: provide a full-precision (32-bit) timeout interval for the logoff timeout service. For more information on new event types, refer to the VM Event System Service (*VMEVENT) described in the CP Programming Services Documentation (SC24-6272-73).
Problem conclusion
Temporary fix
Comments
APAR Information
APAR number
PH57144
Reported component name
OPERATIONS MANA
Reported component ID
5697J1000
Reported release
160
Status
CLOSED UR1
PE
NoPE
HIPER
NoHIPER
Special Attention
YesSpecatt / New Function / Xsystem
Submitted date
2023-09-25
Closed date
2023-09-25
Last modified date
2023-10-31
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI93719
Modules/Macros
GOMMAIN VIEWSPL
Fix information
Fixed component name
OPERATIONS MANA
Fixed component ID
5697J1000
Applicable component levels
R160 PSY UI93719
UP23/10/04 P 2310
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSMR76","label":"Operations Manager for z\/VM"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"160","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
01 November 2023