Error description
If a Column Map definition being imported into the Optim directory contains a long hexadecimal literal value that spans more than one line within the input area it may be truncated and the import may fail with an error message similar tothe following may appear in the summary report: ERROR IN CM mapid.mapname. AROUND RECORD # nn. Value "X'4249414E58494E47404249414E2E58494E47202020202020202020 2020202020202020" Not Valid For SRCTYPE Value "B", Quoted Literal Value Required
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users importing a Column Map containing a * * literal string value that spans more than * * one input line. * **************************************************************** * PROBLEM DESCRIPTION: Literal string values must be enclosed * * in quotation marks. If a literal * * string value is long enough to span * * multiple input records it may be * * truncated during validation and the * * closing quote lost leading to an error. * **************************************************************** * RECOMMENDATION: Apply the fix provided. * **************************************************************** Optim's Column Map import logic did not provide a large enough buffer to hold the entire literal string causing it to be truncated.
Problem conclusion
The faulty logic has been corrected.
Temporary fix
Comments
APAR Information
APAR number
PH56926
Reported component name
OPTIM MOVE FOR
Reported component ID
5655V0700
Reported release
B70
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2023-09-13
Closed date
2023-09-26
Last modified date
2023-10-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
FOP1OSFN FOP9APIM FOPCFPMN FOPCXLIB FOPD2 FOPD2VNN FOPHSTM FOPINS0 FOPMAIN FOPMCMAI FOPMCOLA FOPMCOLP FOPMDXTR FOPMECMN FOPMMCMR FOPMMJBS FOPMMUNU FOPMUXIM FOPODPP FOPOMN FOPRS6 FOPZFMMN FOPZMAIN
Fix information
Fixed component name
OPTIM MOVE FOR
Fixed component ID
5655V0700
Applicable component levels
RB70 PSY UI93740
UP23/09/28 P F309
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU011","label":"Systems - zSystems software"},"Product":{"code":"SG19M"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"B70"}]
Document Information
Modified date:
03 October 2023