After applying PTF UI91557, ABENDS906 occurs with following message: CSV002I REQUESTS FOR MODULE DFSCNVT0 EXCEED MAXIMUM USE COUNT CSV028I ABEND906-08 JOBNAME=SRIO1611 STEPNAME=BMPSTEP It appears DFSCNVT0 is loaded twice for each checkpoint instead of loading DFSCNVT0 and reusing DFSCNVT0 loaded address.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of IBM IMS Program Restart * * Facility for z/OS Version 2 Release 2 * * (FMID=H23D220). * **************************************************************** * PROBLEM DESCRIPTION: After applying UI91557, IMS BMP fails * * with S906 after issueing 16,384 or * * more checkpoints. * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * **************************************************************** After applying UI91557, PRF saves a time stanp using local time in the checkpoint tracing datasets (CTDSs). To calculate the local time, PRF requests to load DFSCNVT0 module. Originally, the loading process should have been bypassed if DFSCNVT0 was already loaded, but there was a flaw in the bypass process, and the loading process was performed at each checkpoint, which caused S906 abend after isueing 16,384 or 32,767 checkpoints.
Problem conclusion
Applying this APAR prevents the Abends.
Temporary fix
Comments
APAR Information
APAR number
PH56680
Reported component name
IMS PGM RESTART
Reported component ID
5655E1400
Reported release
220
Status
CLOSED PER
PE
YesPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2023-08-31
Closed date
2023-10-06
Last modified date
2023-11-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI93906
Modules/Macros
IRTFXSR0 IRTHKIB IRTINCL IRTIXT14 IRTIXT15 IRTJOB IRTPRE00 IRTPRE10 IRTXRI14 IRTXRI15 IRTXSC14 IRTXSC15 IRTZ1000 IRTZJOBS
Fix information
Fixed component name
IMS PGM RESTART
Fixed component ID
5655E1400
Applicable component levels
R220 PSY UI93906
UP23/10/20 P F310 {
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU029","label":"Software"},"Product":{"code":"SSCX8A5","label":"IMS Tools"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"220"}]
Document Information
Modified date:
02 November 2023