Error description
ABENDS0C9 IQCXPACE at X'1096' when running QCF LOAD and with the MAXWAIT statement set as follows: MAXWAIT=00:00:01 S0C9
Local fix
Set the MAXWAIT state to MAXWAIT=00:00:02 or higher to avoid the abend.
Problem summary
**************************************************************** * USERS AFFECTED: All IBM IMS Queue Control Facility for z/OS * * Version 3 Release 2 (FMID=H0GN320) users. * **************************************************************** * PROBLEM DESCRIPTION: ABENDS0C9 IQCXPACE at X'1096' when * * the PACING is used for QCF LOAD * * function and with the MAXWAIT * * statement set as follows: * * MAXWAIT=00:00:01 * * * * If the load on IMS is high and the * * processing time of each message in the * * QCF takes more than 1 second, this * * issue may occur. * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * **************************************************************** The QCF LOAD function with the PACING converts the time it takes to actually insert a message and the time recorded in the IMS log into Clock Value to calculate the wait time between inserting the next message. ABENDS0C9 is caused by incorrect logic when calculating wait time using Clock Value.
Problem conclusion
QCF has been modified to calculate Clock Value accurately.
Temporary fix
Comments
APAR Information
APAR number
PH56467
Reported component name
IMS QUEUE CNTL
Reported component ID
5697E9900
Reported release
320
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2023-08-21
Closed date
2023-09-25
Last modified date
2023-10-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI93705
Modules/Macros
IQCXPACE
Fix information
Fixed component name
IMS QUEUE CNTL
Fixed component ID
5697E9900
Applicable component levels
R320 PSY UI93705
UP23/09/27 P F309
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX8A6","label":"IMS Tools"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"320"}]
Document Information
Modified date:
03 October 2023