Error description

  • Separate LOCATION statistics from STATIME_MAIN
    .
    Additional keywords: IFCID365  IFCID0365  IFCID411
    IFCID0411  IFCID412  IFCID0412  DB2AIV1R5/K
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * Db2 for z/OS users of Statistic traces                       *
    * including Db2ZAI users of System                             *
    * Assessment(SA) and Distributed Connection                    *
    * Control (DCC).                                               *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * IFCID 411 and IFCID 412 are controlled                       *
    * by the STATIME_MAIN system parameter.                        *
    * IFCID 365 is also controlled by                              *
    * STATIME_MAIN when DCC is running.                            *
    * These three Distributed Data Facility                        *
    * (DDF) traces typically very large                            *
    * with many repeating sections that span                       *
    * multiple trace entries per timer                             *
    * interval.                                                    *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    Db2ZAI recommends the timer be set to 10 seconds to reduce the
    SMF volume generated by the location statistics and the size of
    the Db2ZAI tables related to these statistics. However, some
    diagnostic tools are asking Db2 for z/OS customers to set
    STATIME_MAIN to 5 seconds which causes an increase in SMF
    volume and Db2ZAI location table sizes.
    

Problem conclusion

Temporary fix

Comments

  • This APAR adds a new Db2 subsystem parameter, STATIME_DDF, to
    control the interval of location statistics trace records
    IFCID0365, IFCID0411 and IFCID0412. It defaults to zero which
    keeps the existing behavior for compatibility reasons. It
    allows for a time interval from 5 seconds to 5 minutes in 5
    second intervals for all three traces.
    See the ++HOLD ACTION text for information on how to set
    STATIME_DDF to a different value.
    Additional keywords: IFCID365, IFCID 0365, IFCID411,
    IFCID 0411, IFCID412, IFCID 0412, DB2AIV1R5/K
    

APAR Information

  • APAR number

    PH56228

  • Reported component name

    DB2 OS/390 & Z/

  • Reported component ID

    5740XYR00

  • Reported release

    D10

  • Status

    CLOSED UR1

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2023-08-04

  • Closed date

    2023-12-06

  • Last modified date

    2024-01-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI94758 UI94759

Modules/Macros

  • DSNTINMF DSNDQWPZ DSNWZIFD DSNWZIFC DSNTIDXA DSNTIVMD DSNTIJUZ
    DSNTINST DSNTIDXC DSNTIWIA DSNTIDXB DSNTIVIA DSNTIWMD DSNTIWIE
    DSNTIVIE DSN6SYSP DSNWVZXT DSN@XAZP DSNTXAZP DSNTIWPC DSNTIPN
    DSNTIVMN DSNT1MST DSNTIWMN DSNTIVAF DSNTIVIN DSNTIWMS DSNTIVMS
    DSNTIWAF DSNTIWIN
    

Fix information

  • Fixed component name

    DB2 OS/390 & Z/

  • Fixed component ID

    5740XYR00

Applicable component levels

  • RC10 PSY UI94758

       UP23/12/12 P F312

  • RD10 PSY UI94759

       UP23/12/12 P F312

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSEPEK","label":"DB2 for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"D10","Line of Business":{"code":"LOB10","label":"Data and AI"}}]