Error description

  • If RRS is not available in the system on which IIDR CDC for z/OS
    is running, CHC9210E message would be issued to state DB2 RRSAF
    IDENTIFY request has failed, the Return Code is X'00000008', the
    Reason Code is X'00F30091', then CDC z/OS address space suspends
    for shutdown and could not resume for replication even after the
    RRS is available. RRS is one of the z/OS components that are
    required by CDC z/OS to perform its functions, CDC z/OS should
    shut down itself instead of suspend if RRS is not available.
    

Local fix

  • Recycle the CDC z/OS address space.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of IIDR CDC for z/OS                   *
    ****************************************************************
    * PROBLEM DESCRIPTION: If RRS is not available in the system   *
    *                      on which IIDR CDC for z/OS is running,  *
    *                      CHC9210E message would be issued to     *
    *                      state DB2 RRSAF IDENTIFY request has    *
    *                      failed, the Return Code is X'00000008', *
    *                      the Reason Code is X'00F30091', then    *
    *                      CDC z/OS address space suspends for     *
    *                      shutdown and could not resume for       *
    *                      replication even after RRS is available *
    ****************************************************************
    IIDR CDC for z/OS suspends for shutting down and never resumes
    if RRS is detected not available.
    

Problem conclusion

  • RRS is one of the z/OS components that are required by CDC z/OS
    to perform its functions, CDC z/OS should shut down instead of
    suspend if RRS is not available.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH56084

  • Reported component name

    INFO SRVR CDC Z

  • Reported component ID

    5655U7600

  • Reported release

    A21

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2023-07-28

  • Closed date

    2023-09-13

  • Last modified date

    2023-10-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI93320

Modules/Macros

  • CHCDLRGP CHCDLRPF CHCDSCDB CHCDSLGP CHCDSLPF CHCMBARA CHCMBCHS
    CHCMBCHT CHCMBDAN CHCMBDES CHCMBDEU CHCMBELL CHCMBENG CHCMBENP
    CHCMBENU CHCMBESP CHCMBFIN CHCMBFRA CHCMBFRB CHCMBFRC CHCMBFRS
    CHCMBHEB CHCMBISL CHCMBITA CHCMBITS CHCMBJPN CHCMBKOR CHCMBNLB
    CHCMBNLD CHCMBNOR CHCMBPTB CHCMBPTG CHCMBRMS CHCMBRUS CHCMBSVE
    CHCMBTHA CHCMBTRK
    

Fix information

  • Fixed component name

    INFO SRVR CDC Z

  • Fixed component ID

    5655U7600

Applicable component levels

  • RA21 PSY UI93320

       UP23/09/23 P F309

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSTVMA","label":"InfoSphere Data Replication for DB2 for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"10.2.1","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
02 October 2023