Error description

  • The acelerator server suddenly goes offline and gets back
    online after restart.
    This failure happens in conjunction with the execution of a
    multi-row insert statement without parameter markers on an
    accelerator-only table (AOT).
    Internally the accelerator server failed due to a protection
    exception (Signal 11 and core dump "address not mapped to
    object") which forces a restart.
    
    Additional keywords:
    TS011286940 SIGNAL11 coredump AOT MRI parameter marker
    GH/Everest/Customer-Cases/issues/526
    

Local fix

Problem summary

  • Problem Summary:
    The accelerator server suddenly goes offline and gets back
    online after restart.
    This failure happens in conjunction with the execution of a
    multi-row insert statement without parameter markers on an
    accelerator-only table (AOT).
    
    Users Affected:
    Users executing multi-row insert statements on accelerator-only
    tables.
    
    Problem Scenario:
    See Error Description
    
    Problem Symptoms:
    See Error Description
    

Problem conclusion

  • The issue is fixed with Accelerator maintenance level 7.5.11.
    Upgrade your accelerator environments accordingly.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH55467

  • Reported component name

    ANYTCS ACCLTR Z

  • Reported component ID

    5697DA700

  • Reported release

    750

  • Status

    CLOSED DOC

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2023-06-28

  • Closed date

    2023-06-28

  • Last modified date

    2023-06-28

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

[{"Business Unit":{"code":"BU011","label":"Systems - zSystems software"},"Product":{"code":"SG19O"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"750"}]

Document Information

Modified date:
29 June 2023