A fix is available
APAR status
Closed as program error.
Error description
Discrepancy with 56FA records generating duplicate records
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of IBM Z Decision Support Version * * 1.9.0 and IBM Z Performance and Capacity * * Analytics Version 3.1.0 component * * Key Performance Metrics - IMS * * collecting IMS 56FA records. * **************************************************************** * PROBLEM DESCRIPTION: 1. Some transaction counts in table * * KPM_IMS_TRAN_D are double the count * * in IMS_TRANS_D. * * 2. The time value in KPM_IMS_TRAN_H * * does not match the time in IMS_TRAN_H. * **************************************************************** * RECOMMENDATION: Apply the PTFs provided. * **************************************************************** 1. Some transactions generate more than one 56FA records causing the record count to be higher than expected. 2. The collect does not use the time zone offset when collecting 56FA records. The result is a time difference between IMS_TRAN_H and KPM_IMS_TRAN_H.
Problem conclusion
1. The record selection criteria has been modified to correct the transaction count. 2. The update definition has been changed to use the time zone offset in the 56FA record.
Temporary fix
Comments
APAR Information
APAR number
PH55140
Reported component name
TDS FOR Z/OS
Reported component ID
569510100
Reported release
C01
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2023-06-13
Closed date
2023-07-17
Last modified date
2023-08-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI92729 UI92730 UI92731 UI92732
Modules/Macros
DRLRIC1L DRLRID1L DRLRIE1L DRLRIF1L DRLUIC1L DRLUID1L DRLUIE1L DRLUIF1L
Fix information
Fixed component name
TDS FOR Z/OS
Fixed component ID
569510100
Applicable component levels
R901 PSY UI92731
UP23/07/26 P F307
R9A1 PSY UI92732
UP23/07/26 P F307
RC01 PSY UI92729
UP23/07/26 P F307
RCA1 PSY UI92730
UP23/07/26 P F307
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS2DUM","label":"IBM Z Decision Support"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"C01","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
01 August 2023