IBM Support

PH54975: ASN0651E error when LOB length is altered to make it larger

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as new function.

Error description

  • ALTER TYPE that only changes the LENGTH is not replicated.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: 1- All Q Capture users replicating ALTER     *
    *                 TABLE ALTER COLUMN of LOB data type          *
    ****************************************************************
    * PROBLEM DESCRIPTION: 1- Capture gets an error when the LOB   *
    *                      length is altered.                      *
    ****************************************************************
    1- Commands such as ALTER TABLE ADMF001.LOBT1 ALTER COLUMN C3
    SET DATA TYPE CLOB(9M) makes Capture fail.
    

Problem conclusion

  • 1- The code is fixed to handle the alter of LOB column length
    for Q and SQL replication.
    ASNCLP was not updated.
    Function Level: 1140.103
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH54975

  • Reported component name

    WS REPLICATION

  • Reported component ID

    5655L8800

  • Reported release

    B33

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2023-06-06

  • Closed date

    2023-06-23

  • Last modified date

    2023-07-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI92420 UI92421 UI92422 UI92423

Modules/Macros

  • ASN2BASE ASN2SQLZ ASNACMD  ASNADMSP ASNAPPLY ASNCAP   ASNCATM
    ASNCCMD  ASNCCPWK ASNCDINS ASNMCMD  ASNMON   ASNQACMD ASNQAPP
    ASNQCAP  ASNQCCMD ASNQDEP  ASNQEXRP ASNQMFMT ASNQXFMT ASNRBASE
    ASNTDIFF ASNTDSP  ASNTRC
    

Fix information

  • Fixed component name

    WS REPLICATION

  • Fixed component ID

    5655L8800

Applicable component levels

  • RB33 PSY UI92420

       UP23/06/27 P F306

  • RB34 PSY UI92421

       UP23/06/28 P F306

  • RB35 PSY UI92422

       UP23/06/27 P F306

  • RB36 PSY UI92423

       UP23/06/27 P F306

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU011","label":"Systems - zSystems software"},"Product":{"code":"SG19M","label":"InfoSphere Replication Server"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"B33"}]

Document Information

Modified date:
03 July 2023