A fix is available
APAR status
Closed as program error.
Error description
Advanced ACBGEN causes ABENDS0C3 when BUILD PSB=ALL is specified and it processes ACB library on an extended address volume (EAV). The error is caused by XDAP macro to clear ACB library because XDAP macro does not support an extended address volume.
Local fix
N/A
Problem summary
**************************************************************** * USERS AFFECTED: IMS Library Integrity Utilities for z/OS, * * Version 2 Release 2 (FMID=H27P220) users * * who use the Advanced ACBGEN utility. * **************************************************************** * PROBLEM DESCRIPTION: The Advanced ACBGEN causes ABENDS0C3 * * when BUILD PSB=ALL is specified and the * * utility processes ACB library on EAV * * volume. * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * **************************************************************** This APAR fixes the Advanced ACBGEN utility not to cause ABENDS0C3 when BUILD PSB=ALL is specified and the utility processes ACB library on an extended address volume (EAV volume). The error was caused by the XDAP macro when the utility used the XDAP macro to clear the directory entry of the ACB library because the XDAP macro does not support an extended address volume(EAV volume). This APAR modifies the Advanced ACBGEN utility to uses STOW and I option instead of using the XDAP macro.
Problem conclusion
The following module has been changed to fix the problem: FABQDIRX
Temporary fix
Comments
APAR Information
APAR number
PH54903
Reported component name
IMS LIBR INTEG
Reported component ID
5655I4200
Reported release
220
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2023-06-02
Closed date
2023-06-15
Last modified date
2023-07-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI92260
Modules/Macros
FABQDIRX
Fix information
Fixed component name
IMS LIBR INTEG
Fixed component ID
5655I4200
Applicable component levels
R220 PSY UI92260
UP23/06/17 P F306
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU011","label":"Systems - zSystems software"},"Product":{"code":"SG19M","label":"IMS Tools"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"220"}]
Document Information
Modified date:
03 July 2023