IBM Support

PH54722: OMPE V550 JULY 2023 MAINTENANCE UPDATES

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • OMPE V550 July 2023 Maintenance Updates
    

Local fix

  • na
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of Batch Reporting                     *
    *                 Users of the Enhanced 3270 UI                *
    ****************************************************************
    * PROBLEM DESCRIPTION: 1. CICS Task History refers to wrong    *
    *                         Db2 thread history                   *
    *                      2. Db2 Pop-Up Missing in CICS-Db2       *
    *                         Connection (KCPD2S) Workspace        *
    *                      3. Incorrout E3270UI workspaces when    *
    *                         27x132 screen is used.               *
    *                      4. QXSTMLSRT incorrout in Batch         *
    *                         Statistics                           *
    *                      5. LOCSTAT first interval not reported  *
    *                         properly                             *
    *                      6. The Agent Hub connection may fail    *
    *                         after a Hub TEMS fail-over (for Hub  *
    *                         TEMS configured to use Hot Standby   *
    *                         (Fault Toleration Option - FTO).     *
    *                      7. S04E abend during load of PDB table  *
    *                         DB2PMFACCT_GENERAL.                  *
    *                      8. Not all columns in PDB table         *
    *                         DB2PMFACCT_GBUFFER populated with    *
    *                         data.                                *
    *                      9. No Buffer Pool / Group Buffer Pool   *
    *                         details shown in E3270 UI Thread     *
    *                         History.                             *
    ****************************************************************
    * RECOMMENDATION: Apply this PTF.                              *
    ****************************************************************
    1. CICS Task History refers to wrong Db2 thread history.
    2. Db2 Pop-Up Missing in CICS-Db2 Connection (KCPD2S) Workspace.
    3. Missing data when MORE is used to navigate through E3270UI
       workspaces especially 27x132 screens are used.
    4. QXSTMLSRT was not included in delta processing for Statistics
       reports.
    5. LOCSTAT first record lost due to incorrect flag checking.
    6. The Agent Hub connection may fail after a Hub TEMS
       fail-over (for Hub TEMS configured to use Hot Standby
       (Fault Toleration Option -- FTO).
    7. Load job for DB2PMFACCT_GENERAL abends with S04E due to not
       properly initialized field SQL_DI_CPU_C2_P.
    8. Columns PRIMAUTH, ORIGAUTH, CLIENT_ENDUSER, REQ_LOCATION,
       MAINPACK, RQ_LOCATION in PDB table DB2PMFACCT_GBUFFER
       are not populated with data.
    9. No Buffer Pool / Group Buffer Pool details shown in E3270
       UI Thread History panels.
    

Problem conclusion

  • 1. Corrected key field used for CICS/DB2 workspace linkage.
    2. Corrected Db2 Pop-up.
    3. Corrected incorrect output from some E3270UI workspaces when
       27x132 screen is used.
    4. Included QXSTMLSRT in delta processing for Statistics.
    5. Corrected LOCSTAT flag checking.
    6. Improved Hot Standby fail-over connection processing.
    7. Field SQL_DI_CPU_C2_P initialized while creating Batch
       Accounting FILE to be loaded to DB2PMFACCT_GENERAL.
    8. Data for columns PRIMAUTH, ORIGAUTH, CLIENT_ENDUSER,
       REQ_LOCATION, MAINPACK, RQ_LOCATION in PDB table
       DB2PMFACCT_GBUFFER are externalized in a load file.
    9. Corrected processing to properly show Buffer and Group
       Buffer Pool details in E3270 Thread History panels
       KDPHBP and KDPHGBP.
    
    Keywords.
    ---------
    KCPD2S KDPCPDBI MSGKO2D0009E KDPACC71 KDPACC72 KDPDYNST
    KDPAGENT KDPPLEX KDPHBP KDPHGBP SQL_DI_CPU_C2_P
    
    Additional APAR CLOSED: PH54680 PH54468 PH54500 PH55198
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH54722

  • Reported component name

    OM XE DB2PE/PM

  • Reported component ID

    5655OPE00

  • Reported release

    550

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2023-05-24

  • Closed date

    2023-07-26

  • Last modified date

    2023-08-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI92898

Modules/Macros

  • DGOAFGBP DGOAFGEN DGOBGENL DGOBSRAL DGOBSRBN DGOBSRCM DGOBSRDD
    DGOBSRLG DGOBSRLK DGOBSRLO DGOBSROC DGOBSRPO DGOBSRQP DGOBSRRI
    DGOBSRSH DGOBSRSP DGOBSRSQ DGOBSRSS DGOBSRTM DGOBSTAL DGOBSTBN
    DGOBSTCM DGOBSTDD DGOBSTLG DGOBSTLK DGOBSTLO DGOBSTOC DGOBSTPO
    DGOBSTQP DGOBSTRI DGOBSTSH DGOBSTSP DGOBSTSQ DGOBSTSS DGOBSTTM
    DGOER000 DGOFPDAT DGOFSXST DGOFUCA1 DGOFUCAL DGOFUFAC DGOFUFDI
    DGOPMICO DGOPSB10 DGOPSB20 DGOPSC10 DGOPSC20 DGOPSCNV DGOSACMG
    DGOSACU2 DGOSACUM DGOSAPAW DGOSAPTS DGOSBLKX DGOSBORD DGOSBORE
    DGOSCREC DGOSFILE DGOSFMTQ DGOSFMTR DGOSFMTS DGOSFMTT DGOSGENS
    DGOSI225 DGOSI365 DGOSI411 DGOSI412 DGOSP365 DGOSP411 DGOSP412
    DGOSREDC DGOSREPG DGOSREPM DGOSRMGS DGOSSAVE DGOSSTDA DGOSSWSR
    DGOSTRAC DGOVCRDB DGOVFTAB DGOVFTIN DGOVMSTR DGOVRA   DGOVSCLO
    DGOVSCNI DGOVSCNT DGOVSFLR DGOVSGFT DGOVSLOC DGOVSORT DGOVSQFM
    DGOVSTQL DGOVUDAT DGOVUFTL FPECMDAT FPEFUCAL FPEUCBPR FPEVFTM
    FPEVSFLR FPEVZMAI KD5AGENT KDPACC71 KDPACC72 KDPCPDBI KDPDYNST
    KDPHBP   KDPPLEX  KO2BDDTL KO2CCAFB KO2CCAPB KO2CINTB KO2CPC52
    KO2CPC5A KO2CPC5S KO2CPC62 KO2CPC6A KO2CPC6S KO2CWRKB KO2DDSB2
    KO2DDSBA KO2DDSBS KO2DSIF2 KO2DSIFA KO2DSIFS KO2OH2IB KO2OQAL2
    KO2OQALA KO2OQALS
    

Fix information

  • Fixed component name

    OM XE DB2PE/PM

  • Fixed component ID

    5655OPE00

Applicable component levels

  • R550 PSY UI92898

       UP23/07/28 P F307

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSZJXP","label":"DB2 Tools for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"550","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
01 August 2023