Error description

  • The IBM Transformation Extender Healthcare Payer packs,
    Compliance Check process is reporting an invalid subelement
    position for subelement errors that occur after a date
    subelement (D8 or RD8) in a Composite Element.  An error in the
    HI segment is a typical case for this.
    
    For example, in the HI*BE segment that has all subelements
    present, with the last subelement (9) being an invalid code
    value, such as the X in the following line.
    
    HI*BE:A1:RD8:20220101-20220102:1:9:999:ABC:X
    
    In the resulting 999, this is incorrectly reported as subelement
    11 being in error.
    
    IK3*HI*32*2300*8
    IK4*1:11**I6*X
    
    There is no subelement 11 and should be subelement 9.
    
    IK3*HI*32*2300*8
    IK4*1:9**I6*X
    

Local fix

  • ITXCQ - ITX00061890
    TR / TR
    Circumvention: None
    

Problem summary

  • Users Affected:
    IBM Transformation Extender Pack for Healthcare HIPAA
    
    Problem Description:
    
    Invalid subelement is reported in the 999 for HI segment.
    
    Platforms Affected:
    ALL
    

Problem conclusion

  • Compliance Check maps updated so that if HI segment has a date
    subelement- either D8 or RD8, if an error reported on subelement
     after the date will have the correct subelement number.
    
    Applies to:
    Healthcare Pack HIPAA 10.1.0, 10.2.0, 10.2.1
    
    Fixed in the next service packs and releases.
    
    To obtain the fix for this APAR:
    
    To see if the next service pack or product release is available,
    check the IBM Transformation Extender Downloads page:
    http://www.ibm.com/support/entry/portal/product/other_software/t
    ransformation_extender
    
    If the service pack or product release is available, download it
    from Fix Central:
    http://www.ibm.com/support/fixcentral/
    
    If the service pack or product release is not available and you
    require the APAR fix immediately, request a Limited Availability
    Interim Fix (LAIF) by opening a PMR:
    http://www.ibm.com/support/servicerequest/Home.action
    
    Prior to version 9.0.0, IBM Transformation Extender was called
    IBM WebSphere Transformation Extender.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH54358

  • Reported component name

    TX HIPPA EDI

  • Reported component ID

    5724M6100

  • Reported release

    A10

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2023-05-05

  • Closed date

    2023-06-14

  • Last modified date

    2023-06-14

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    TX HIPPA EDI

  • Fixed component ID

    5724M6100

Applicable component levels

[{"Business Unit":{"code":"BU029","label":"Software"},"Product":{"code":"SSVSD8","label":"Transformation Extender"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"A10"}]

Document Information

Modified date: