PH54237: CHANGE PACKAGE PROCESSING TO READY OR LIST PACKAGED RESOURCES FAILS RC=16 RSN=0010 WHEN THE NUMBER OF CICS CONFIGURATIONS

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

 

APAR status

  • Closed as program error.

Error description

  • When the number of defined CICS Configurations exceeds the limit
    set in the READY processing program CCVARDY, the API request
    fails with the following CCVLOG symptoms:
    
          1.  READY API request to ready a change package
              CCV5210E Severe error for Command READY.
              CCV9999I TASKNO=nnnnnnnn
              CCV9999I RC=SVERR
              CCV9999I MODID=X'0011'
              CCV9999I RSN=X'0010'
              CCV9999I INFO=X'F1F1F3F7' 1137
              CCV9999I INFO2=X'C3D6D5C6C9C7E3C2' CONFIGTB
              CCV9999I USERID=xxxxxxx
          2.  LIST API request to list change package resources
              CCV5210E Severe error for Command LIST. Processing
                       terminated.
              CCV9999I TASKNO=nnnnnnnn
              CCV9999I RC=SVERR
              CCV9999I MODID=X'0006'
              CCV9999I RSN=X'0010'
              CCV9999I INFO=X'F0F1F0F2' 0102
              CCV9999I INFO2=X'C3C3E5C1D9C4E840' CCVARDY
              CCV9999I USERID=xxxxxxx
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of CICS Configuration Manager.     *
    ****************************************************************
    * PROBLEM DESCRIPTION: Change package processing to READY or   *
    *                      LIST packaged resources fails with      *
    *                      RC=16 RSN=0010 when number of CICS      *
    *                      Configurations exceeds 5000.            *
    ****************************************************************
    When the number of defined CICS Configurations exceeds the limit
    set in the READY processing program CCVARDY, the API request
    fails with the following CCVLOG symptoms:
    1.  READY API request to ready a change package
             CCV5210E Severe error for Command READY.
             CCV9999I TASKNO=nnnnnnnn
             CCV9999I RC=SVERR
             CCV9999I MODID=X'0011'
             CCV9999I RSN=X'0010'
             CCV9999I INFO=X'F1F1F3F7' 1137
             CCV9999I INFO2=X'C3D6D5C6C9C7E3C2' CONFIGTB
             CCV9999I USERID=xxxxxxx
    2.  LIST API request to list change package resources
             CCV5210E Severe error for Command LIST. Processing
             terminated
             CCV9999I TASKNO=nnnnnnnn
             CCV9999I RC=SVERR
             CCV9999I MODID=X'0006'
             CCV9999I RSN=X'0010'
             CCV9999I INFO=X'F0F1F0F2' 0102
             CCV9999I INFO2=X'C3C3E5C1D9C4E840' CCVARDY
             CCV9999I USERID=xxxxxxx
    

Problem conclusion

  • CICS Configuration Manager is corrected.  An internal table for
    CICS Configuration definitions specified a limit of 5000 entries
    in the CCVARDY ready-processing program.  The limit has been
    increased to 15000.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH54237

  • Reported component name

    CICS CONFIG MGR

  • Reported component ID

    5697CIC00

  • Reported release

    540

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2023-04-29

  • Closed date

    2023-05-12

  • Last modified date

    2023-06-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI91780

Modules/Macros

  • CCVARDY
    

Fix information

  • Fixed component name

    CICS CONFIG MGR

  • Fixed component ID

    5697CIC00

Applicable component levels

  • R540 PSY UI91780

       UP23/05/16 P F305