Error description

  • Task user storage gets corrupted with VSAM file record data.
    A FCP Free BUFFER chain header has been corrupted with an
    address of task storage.
    .
    The sequence of API commands issued by the application leading
    to the problem is as follows:
    EXEC CICS STARTBROWSE FILE
    EXEC CICS READ_NEXT FILE SET
    EXEC CICS READ FILE SET UPDATE
    EXEC CICS REWRITE FILE
    .
    Then the application issues an EXEC CICS SYNCPOINT ROLLBACK.
    .
    The READ_NEXT command getmains its SET storage and places the
    address in an associated FRTE.
    The READ UPDATE command getmains its SET storage, and places the
    address in an associated FRTE.
    On exit from the REWRITE command, the FRTE for the READ UPDATE
    gets released and the SET storage address now appears in the
    FLAB (flab_setu_control) for the file.
    At this point, there is a SET address for the Browser's
    READ_NEXT in a FRTE and the SET address for the READ UPDATE in
    the flab_setu_control.
    Code in DFHFCFR checks if the buffer address in the FRTE is
    different to the SET address in the FLAB.
    If so, then the FRTE SET address is placed on the Free Buffer
    chain. This is incorrect, the address in the FRTE is task
    storage and not from the FCP_256 subpool.
    
    The free buffer chain now contains a storage address that does
    not belong to file control.
    Consequently, when file control needs a SET storage address, it
    takes the next buffer from the free buffer chain causing
    symptoms such as storage violations, abends in file control and
    abends in VSAM.
    Additional symptoms:
    Storage Violations SM0102
    IGW400I ABEND request GET with options 22870000
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All CICS users.                              *
    ****************************************************************
    * PROBLEM DESCRIPTION: An FCP Free BUFFER chain header has     *
    *                      been corrupted with an address of task  *
    *                      storage when preparing to back out a    *
    *                      FRTE for a browse operation.            *
    ****************************************************************
    An EXEC CICS SYNCPOINT ROLLBACK command issued after the
    following sequence of File Control commands caused CICS to place
    the address of task storage (FCSS SET storage used by file
    control) onto the head of the buffer free chain.
    
    EXEC CICS STARTBR FILE
    EXEC CICS READ_NEXT FILE SET
    EXEC CICS READ FILE UPDATE SET
    EXEC CICS REWRITE FILE
    
    Later, when File Control needs a SET storage address and takes
    the address from the head of the buffer free chain,  it may
    cause symptoms such as storage violations, abends in file
    control and abends in VSAM.
    

Problem conclusion

  • DFHFCFR has been changed to not place the frt_data_buffer
    address onto the free buffer chain when preparing to back
    out a FRTE for a browse operation.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH54109

  • Reported component name

    CICS TS Z/OS V5

  • Reported component ID

    5655Y0400

  • Reported release

    100

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2023-04-24

  • Closed date

    2023-06-30

  • Last modified date

    2023-07-04

  • APAR is sysrouted FROM one or more of the following:

    PH51344

  • APAR is sysrouted TO one or more of the following:

    UI92552 UI92553

Modules/Macros

  • DFHFCFR
    

Fix information

  • Fixed component name

    CICS TS Z/OS V5

  • Fixed component ID

    5655Y0400

Applicable component levels

  • R100 PSY UI92553

       UP23/07/04 I 1000

  • R200 PSY UI92552

       UP23/07/04 I 1000

Fix is available