APAR status
Closed as program error.
Error description
Recent maintenance has introduced code that uses instructions that are not available on older zArchitecture hardware that is still serviced and supported. On such hardware the new instruction will cause an ABEND S0C1.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of InfoSphere CDC for z/OS. * **************************************************************** * PROBLEM DESCRIPTION: An ABEND S0C1 occurs during product * * startup. * **************************************************************** Recent maintenance has introduced code that uses instructions that are not available on older zArchitecture hardware that is still serviced and supported. On such hardware the new instruction will cause an ABEND S0C1.
Problem conclusion
The assembly module CHCITCSV has been updated to fix the issue.
Temporary fix
Comments
APAR Information
APAR number
PH54108
Reported component name
INFO SRVR CDC Z
Reported component ID
5655U7600
Reported release
A21
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2023-04-24
Closed date
2023-05-10
Last modified date
2023-06-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI91759
Modules/Macros
CHCITCSV
Fix information
Fixed component name
INFO SRVR CDC Z
Fixed component ID
5655U7600
Applicable component levels
RA21 PSY UI91759
UP23/05/18 P F305