IBM Support

PH53720: MESSAGE CHC0330E AND CHC1522E MAY BE ISSUED IF DB2 CONFIGURATION KEYWORD TRUNCATE IS CONFIGURED AS RESTRICT_TRIGGERS, AFTER WHIC

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • When DB2 configuration keyword TRUNCATE is configured as
    RESTRICT_TRIGGERS, IIDR CDC for z/OS replicates source TRUNCATE
    IMMEDIATE operation as a CLEAR message. However, if the TRUNCATE
    IMMEDIATE operation somehow fails before it can succeed, CDC
    would end the replication after reporting message CHC0330E and
    CHC1522E.
    

Local fix

  • Configure the keyword TRUNCATE to be OFF.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of IIDR CDC for z/OS                   *
    ****************************************************************
    * PROBLEM DESCRIPTION: When TRUNCATE keyword in the CHCDBMxx   *
    *                      member of the configuration dataset is  *
    *                      configured as RESTRICT_TRIGGERS, IIDR   *
    *                      CDC for z/OS replicates source TRUNCATE *
    *                      IMMEDIATE operation as a CLEAR message. *
    *                      However, if the TRUNCATE IMMEDIATE      *
    *                      operation somehow fails before it can   *
    *                      succeed, CDC ends the replication after *
    *                      reporting message CHC0330E and CHC1522E *
    ****************************************************************
    The logic to handle TRUNCATE IMMDEIATE operation does not
    process the failure of TRUNCATE IMMEDIATE properly, this causes
    message CHC0330E and CHC1522E to be issued and replication to
    fail.
    

Problem conclusion

  • The logic to handle TRUNCATE IMMDEIATE operation has been
    improved.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH53720

  • Reported component name

    INFO SRVR CDC Z

  • Reported component ID

    5655U7600

  • Reported release

    A21

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2023-04-05

  • Closed date

    2023-11-20

  • Last modified date

    2023-12-06

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI94543

Modules/Macros

  • CHCDSCPF CHCSTGSP
    

Fix information

  • Fixed component name

    INFO SRVR CDC Z

  • Fixed component ID

    5655U7600

Applicable component levels

  • RA21 PSY UI94543

       UP23/12/06 I 1000

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSTVMA","label":"InfoSphere Data Replication for DB2 for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"10.2.1","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
06 December 2023