Error description
Plugin does not allow for content body larger than 1386820698 in WAS855. This is not an issue in WAS90 the code need to be back ported for the large body changes from plugin v9 to v855
Local fix
na
Problem summary
**************************************************************** * USERS AFFECTED: IBM WebSphere Application Server web * * server plugin users * **************************************************************** * PROBLEM DESCRIPTION: Plugin does not tranfer non-chunked * * data larger than 2GB in version 8.5. * * Version 9.0 may log incorrect length. * **************************************************************** * RECOMMENDATION: * **************************************************************** When http requests or responses are transmitted with a fixed size (content-length header present), plugin does not transfer the data. Data is transferred as expected in version 9 but plugin tracing may report an incorrect size for the data.
Problem conclusion
Backported the function from WAS90 to WAS855. Corrected print formatter so that correct size is reported when the data length is written in plugin's trace file. The fix for this APAR is targeted for inclusion in fix pack 8.5.5.24 and 9.0.5.17. For more information, see 'Recommended Updates for WebSphere Application Server': https://www.ibm.com/support/pages/node/715553
Temporary fix
Comments
APAR Information
APAR number
PH53629
Reported component name
WEBS APP SERV N
Reported component ID
5724H8800
Reported release
850
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2023-03-30
Closed date
2023-05-10
Last modified date
2023-05-10
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
WEBS APP SERV N
Fixed component ID
5724H8800
Applicable component levels
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSEQTP","label":"WebSphere Application Server"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.5","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
11 May 2023