Error description

  • ABSTRACT:  Object Compare does not substitute COMPRESS YES
    FIXEDLENGTH with COMPRESS YES on Db2 z/OS Function levels less
    than FL509 where FIXEDLENGTH is not supported
    
    
    DESCRIPTION:  If the source is at function level V12R1M509 and
    above while the target is below V12R1M509, Object Compare does
    not substitute COMPRESS YES FIXEDLENGTH with its equivalent
    COMPRESS YES.
    
    
    It currently issues an ADB73292E message with an RC=12, it
    should instead issue a new warning message informing the user
    that a substitution has taken place for the COMPRESS and end
    with RC = 4. For COMPRESS YES HUFFMAN, as that is not supported
    below V12R1M509, it will still issue the ADB73292E message but
    return RC = 8 instead.
    

Local fix

  • na
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of Db2 Administration Tool for z/OS    *
    ****************************************************************
    * PROBLEM DESCRIPTION: Object Compare does not treat COMPRESS  *
    *                      YES FIXEDLENGTH as equivalent to        *
    *                      COMPRESS YES on lower Db2 function      *
    *                      levels.                                 *
    ****************************************************************
    In function levels lower than V12R1M509, Object Compare issues
    an ADB7392E message and returns RC = 12 when it encounters
    COMPRESS YES FIXEDLENGTH or COMPRESS YES HUFFMAN.
    Keywords: COMPRESS
    

Problem conclusion

  • The problem has been resolved.
    Object Compare will now substitute COMPRESS YES FIXEDLENGTH with
    the equivalent COMPRESS YES, issue the new ADB7410W message, and
    return RC = 4. For HUFFMAN, Object Compare will issue the
    updated ADB7392E message and return RC = 8
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH53588

  • Reported component name

    DB2 ADMIN TOOL

  • Reported component ID

    568851500

  • Reported release

    C10

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2023-03-29

  • Closed date

    2023-06-12

  • Last modified date

    2023-07-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI92208 UI92209

Modules/Macros

  • ADB2CM3  ADB2CME  ADB2CMR  ADB2CMT  ADB7000
    

Fix information

  • Fixed component name

    DB2 ADMIN TOOL

  • Fixed component ID

    568851500

Applicable component levels

  • RC10 PSY UI92208

       UP23/06/15 P F306

  • RD10 PSY UI92209

       UP23/06/15 P F306

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU011","label":"Systems - zSystems software"},"Product":{"code":"SG19M","label":"DB2 Tools for z\/OS"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"12.1.0"}]

Document Information

Modified date: