PH53507: SEVERITY CANNOT BE SET EVEN IF EXCEPTION IS DETECTED ON THE AUTONOMICS DIRECTOR SERVER.

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • The severity of exception is obtained from exception definition
    table. However, since valid exception definition table does not
    exist in the Autonomics Director server, the severity
    information cannot be obtained. With this APAR, the Autonomics
    Director server terminates abnormally when this situation is
    detected.
    In addition, the following defect will be fixed.
    The Autonomics Director loads and deletes the module of HKTRERD
    whenever policy evaluation runs. However, load and delete did
    not work properly. So load count for HKTRERD was increased each
    policy evaluation. As the result, load count reached 32767 and
    CSV002I message was issued. With this APAR, the Autonomics
    Director server deletes HKTRERD correctly.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of IBM IMS Tools Base for z/OS     *
    *                 Version 1 Release 7 (FMID: HAHN170) who use  *
    *                 the Autonomics Director.                     *
    ****************************************************************
    * PROBLEM DESCRIPTION: The severity of exception is not be set *
    *                      even if the exception is detected on    *
    *                      the Autonomics Director server.         *
    ****************************************************************
    * RECOMMENDATION: Apply the maintenance for this APAR and      *
    *                 restart the Autonomics Director server.      *
    ****************************************************************
    The severity of exception is obtained from the exception
    definition table. However, since the valid exception definition
    table does not exist in the Autonomics Director server,
    the severity information cannot be obtained.
    To avoid a situation of running the Autonomics Director server
    without the exception definition table available, the fix for
    this APAR causes the Autonomics Director server to terminate
    abnormally if this situation is detected.
    
    In addition, the following defect is fixed.
    
    The Autonomics Director loads and deletes the module of HKTRERD
    whenever policy evaluation runs. However, load and delete did
    not work properly. So load count for HKTRERD was increased each
    policy evaluation. As the result, load count reached 32767 and
    CSV002I message was issued. With this APAR, the Autonomics
    Director server deletes HKTRERD correctly.
    

Problem conclusion

  • The following modules have been modified:
    IAVDSPOL IAVD0ENU IAVUXQXD IAVUGRN BSNWRECN
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH53507

  • Reported component name

    IMS TOOLS BASE

  • Reported component ID

    5655V9300

  • Reported release

    170

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2023-03-26

  • Closed date

    2023-05-11

  • Last modified date

    2023-06-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI91763

Modules/Macros

  • BSNWRECN IAVD0ENU IAVDSPOL IAVUGRN  IAVUXQXD
    

Publications Referenced
SC27985303    

Fix information

  • Fixed component name

    IMS TOOLS BASE

  • Fixed component ID

    5655V9300

Applicable component levels

  • R170 PSY UI91763

       UP23/05/13 P F305

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU011","label":"Systems - zSystems software"},"Product":{"code":"SG19O","label":"IMS Tools"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"170"}]

Document Information

Modified date:
07 June 2023