IBM Support

PH53178: RECON ACCESS PROCESS FAILS WITH MESSAGE DSP1188A THEN TERMINATES WITH ABENDUU3933

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • RECON access process fails with message DSP1188A then terminates
    with ABENDUU3933 in Image Copy function of IMS HP Image Copy,
    when it is scheduled by DFSRRC00 process as IMS compatible JCL
    

Local fix

  • N/A
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All IMS High Performance Image Copy for      *
    *                 z/OS Version 4.2 users ( FMID=H1J0420 )      *
    ****************************************************************
    * PROBLEM DESCRIPTION: IMS HP Image Copy terminates with       *
    *                      ABEND U3933 ( ABENDU3933 ) and message  *
    *                      FABJ4095E ( MSGFABJ4095E ) when the     *
    *                      following conditions are met.           *
    *                      - Invoke the Image Copy function by     *
    *                        using the IMS Region Controller       *
    *                        program (DFSRRC00).                   *
    *                      - DBRC is active.                       *
    *                      - The name of IMSplex or id of DBRC     *
    *                        group is specified as DFSRRRC00       *
    *                        parameters.                           *
    ****************************************************************
    * RECOMMENDATION: Apply the maintenance for this APAR          *
    ****************************************************************
    IMS HP Image Copy terminates with ABEND U3933 ( ABENDU3933 )
    and message FABJ4095E ( MSGFABJ4095E ) when the following
    conditions are met.
    - Invoke the Image Copy function by using the IMS Region
      Controller program (DFSRRC00).
    - DBRC is active.
    - The name of IMSplex or id of DBRC group is specified as
      DFSRRRC00 parameters.
    
    IMS HP Image Copy uses DBRC API macro (DSPAPI) to obtain the
    RECON level. DBRC API process gets IMSplex name and DBRC group
    id from EXEC parameter in JOB step, but the expected format is
    different from the format of the DFSRRC00 parameter.
    DBRC API cannot obtain the correct IMSplex name and DBRC group
    id, then RECON access is denied with message DSP1136A
    ( MSGDSP1136A ) and DSP1188A ( MSGDSP1188A ).
    Therefore, IMS HP Image Copy terminates with ABEND U3933 and
    message FABJ4095E.
    

Problem conclusion

  • When invoking IMS HP Image Copy DFSUDMP0 from DFSRRC00, IMS HP
    Image Copy converts the IMSplex name and DBRC group id
    parameter format of DFSRRC00 into the format that can be used by
    the DBRC API before scheduling the DBRC API initialization
    process. IMS HP Image Copy restores the parameter format after
    DBRC API process is complete.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH53178

  • Reported component name

    IMS HP IMAGE CO

  • Reported component ID

    5655K9600

  • Reported release

    420

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2023-03-13

  • Closed date

    2023-03-29

  • Last modified date

    2023-04-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI91194

Modules/Macros

  • FABJDMP2 FABJDMP3 FABJDMP4 FABJDMP5 FABJDMP9 FABJDMPA FABJDMPB
    

Fix information

  • Fixed component name

    IMS HP IMAGE CO

  • Fixed component ID

    5655K9600

Applicable component levels

  • R420 PSY UI91194

       UP23/03/31 P F303

Fix is available