Error description

  • Although the setting of the resource overrides in the SIT itself
    was never seen as a usecase, it is also a beneficial feature to
    have the resource overrides in the SIT macro
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All CICS Users.                              *
    ****************************************************************
    * PROBLEM DESCRIPTION: Resource overrides ( RESOVERRIDES )     *
    *                      added in CICS TS V6.1 as a SIT override *
    *                      only.                                   *
    ****************************************************************
    RESOVERRIDES is only allowed as a SIT override and not assembled
    in the SIT macro.
    Attempting to assemble a SIT table containing RESOVERRIDES=
    before applying this APAR will result in 'ASMA017W Undefined
    keyword parameter'.
    

Problem conclusion

  • Code has been added to allow the RESOVERRIDES to be included in
    the SIT macro.
    
    The IBM documentation describing the contents of the default
    system initialization table has been updated to include
    
    Parameter       Default value      Description
    
    RESOVERRIDES=                      Resource Definition overrides
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH53177

  • Reported component name

    CICS TS Z/OS V6

  • Reported component ID

    5655YA100

  • Reported release

    400

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    YesSpecatt / New Function / Xsystem

  • Submitted date

    2023-03-12

  • Closed date

    2023-06-08

  • Last modified date

    2023-07-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI92143

Modules/Macros

  • DFHPADUF DFHPAIN  DFHPARC  DFHPASY  DFHSIT   DFHSIT$$
    

Fix information

  • Fixed component name

    CICS TS Z/OS V6

  • Fixed component ID

    5655YA100

Applicable component levels

  • R400 PSY UI92143

       UP23/06/15 P F306  

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGMGV","label":"CICS Transaction Server"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"6.1","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date:
03 July 2023