A fix is available
APAR status
Closed as program error.
Error description
When the LONG-RUNNING READER value on DB2 installation panel DSNTIPE is non-zero, message DSNB260I may be issued for the CHCSDTxx plan used by CDC for z/OS. Specifically, DB2 DISPLAY BLOCKERS DETAIL command shows that the resources that are held by CDC SDT task are metadata table DMMD_TABLE_VERSION and DMMD_COLUMN_VERSION.
Local fix
REROG DB2 SYSTSTAB table space.
Problem summary
**************************************************************** * USERS AFFECTED: Users of IIDR CDC for z/OS * **************************************************************** * PROBLEM DESCRIPTION: When the LONG-RUNNING READER value on * * DB2 installation panel DSNTIPE is * * non-zero, message DSNB260I may be * * issued for the CHCSDTxx plan opened by * * IIDR CDC for z/OS. Specifically, DB2 * * DISPLAY BLOCKERS DETAIL command shows * * that the resources held by CDC SDT task * * are meta data table DMMD_TABLE_VERSION * * and DMMD_COLUMN_VERSION. * **************************************************************** A COMMIT is missing after the SELECT for meta data table DMMD_TABLE_VERSION and DMMD_COLUMN_VERSION, this may lead DB2 message DSNB260I to be issued for CDC CHCSDTXX plan.
Problem conclusion
A COMMIT has been added after the SELECT for meta data table DMMD_TABLE_VERSION and DMMD_COLUMN_VERSION.
Temporary fix
Comments
APAR Information
APAR number
PH53146
Reported component name
INFO SRVR CDC Z
Reported component ID
5655U7600
Reported release
A21
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2023-03-10
Closed date
2023-03-22
Last modified date
2023-05-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI91078
Modules/Macros
CHCTVHDL
Fix information
Fixed component name
INFO SRVR CDC Z
Fixed component ID
5655U7600
Applicable component levels
RA21 PSY UI91078
UP23/04/14 P F304
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSTVMA","label":"InfoSphere Data Replication for DB2 for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"10.2.1","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
03 May 2023