IBM Support

PH52843: S0C4 ABEND OR SYSTEM ERROR WHILE PROCESSING JOIN COMMAND IN ARCHIVE/EXTRACT FILE BROWSE

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • While issuing a JOIN command from within a browse session of an
    Archive or extract file an S0C4 ABEND or SYSTEM ERROR may be
    encountered:
    
    System Completion Code=0C4 From entry point edprep at
    statement 2788
    
    Join Compile failed
    DB2Rel=1215(NFM), Rel=11.7.0
    Code=-1, AuxInfo=rc=9003
    01  FOPABROW 20230123 PH50193  (002756) ARDMActivateTable
    02  FOPDETCH 20230123 PH50193  (000715) AT_FetchSet
    03  FOPEJOIN 20230123 PH50193  (002721) JoinTables
    04  FOPEJOIN 20230123 PH50193  (000837) Join
    05  FOPELINE 20230123 PH50193  (004883) JoinHandleReturn
    06  FOPEDRIV 20230123 PH50193  (001180) EditAD
    07  FOPABROW 20230123 PH50193  (004025) BrowsePerform
    08  FOPABROW 20230123 PH50193  (001133) ArcBrowse
    09  FOPAMAIN 20230123 PH50193  (000446) ArcHighLevel
    10  FOPJINI  20230123 PH50193  (000540) StartJobSubmission
    11  FOPMCALL 20220720 PH45127  (001749) CallJSub
    12  FOPMMENU 20230123 PH50193  (001795) PromptDM
    13  FOPMMENU 20230123 PH50193  (000948) PromptMain
    14  FOPMMAIN 20230123 PH50193  (001003) Main
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Optim users joining tables in an Access      *
    *                 session.                                     *
    ****************************************************************
    * PROBLEM DESCRIPTION: If tables are JOINed in an Access       *
    *                      browse or edit session and a SORT       *
    *                      primary command is entered followed by  *
    *                      a JOIN to another table, a System Error *
    *                      may occur.                              *
    ****************************************************************
    * RECOMMENDATION: Apply the fix provided.                      *
    ****************************************************************
    Due to an error in Optim processing a reference to an invalid
    control block may be made during the JOIN process.
    

Problem conclusion

  • The error has been corrected.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH52843

  • Reported component name

    OPTIM MOVE FOR

  • Reported component ID

    5655V0700

  • Reported release

    B70

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2023-02-24

  • Closed date

    2023-03-20

  • Last modified date

    2023-04-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • FOP4PEMN FOP9APIM FOPCFPMN FOPDYER6 FOPHSTM  FOPMAIN  FOPMAMAI
    FOPMCBMN FOPMDMAI FOPMDPRC FOPMDXTR FOPMECMN FOPMEMAI FOPMMCMR
    FOPMMJBS FOPMMUTL FOPOMN   FOPRS10  FOPRS3   FOPSYER1 FOPSYER2
    FOPSYER3 FOPZFBMN FOPZFMMN
    

Fix information

  • Fixed component name

    OPTIM MOVE FOR

  • Fixed component ID

    5655V0700

Applicable component levels

  • RB70 PSY UI91033

       UP23/03/21 P F303

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU011","label":"Systems - zSystems software"},"Product":{"code":"SG19M"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"B70"}]

Document Information

Modified date: