Error description
The severity of exception is obtained from exception definition table. However, since valid exception definition table does not exist in the Autonomics Director server, the severity information cannot be obtained. With this APAR, the Autonomics Director server terminates abnormally when this situation is detected.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of IBM IMS Tools Base for z/OS * * Version 1 Release 6 (FMID: HAHN160) who use * * the Autonomics Director. * **************************************************************** * PROBLEM DESCRIPTION: The severity of exception is not be set * * even if the exception is detected on * * the Autonomics Director server. * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR and * * restart the Autonomics Director server. * **************************************************************** The severity of exception is obtained from the exception definition table. However, since the valid exception definition table does not exist in the Autonomics Director server, the severity information cannot be obtained. To avoid a situation of running the Autonomics Director server without the exception definition table available, the fix for this APAR causes the Autonomics Director server to terminate abnormally if this situation is detected.
Problem conclusion
The following modules have been modified: IAVDSPOL IAVD0ENU IAVUXQXD
Temporary fix
Comments
APAR Information
APAR number
PH52782
Reported component name
IMS TOOLS BASE
Reported component ID
5655V9300
Reported release
160
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2023-02-22
Closed date
2023-03-09
Last modified date
2023-04-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI90897
Modules/Macros
IAVD0ENU IAVDSPOL IAVUXQXD
| SC19437608 |
Fix information
Fixed component name
IMS TOOLS BASE
Fixed component ID
5655V9300
Applicable component levels
R160 PSY UI90897
UP23/03/11 P F303
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCJN3E","label":"IMS Tools"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"160"}]
Document Information
Modified date:
03 April 2023