Error description

  • HIPAA Compliance Reports Failure when 837I 2300 HI*BE Segments
    have missing Value Code Amounts.
    
    When the Health Care Information Code - Value Information
    Segment (837I 2300 HI with HI01-01="BE") has missing Value Code
    Amounts (HInn-05), an incomplete data audit condition is
    triggered, the 999 does not include any element or sub-element
    level detail, and the 277CA Response status for the claim is not
    correct.
    
    Involves excess trailing delimiters and the "E15" data audit
    error code.
    

Local fix

  • ITXCQ - ITX00061773
    LV / LV
    Circumvention: None
    

Problem summary

  • Users Affected:
    IBM Transformation Extender Pack for Healthcare HIPAA
    
    Problem Description:
    When 837P data has HI0n01=BE, and HI0n05 missing with all
    subelement delimiters present, data fails for entire segment and
     claim level rejection processing stopped.
    
    Platforms Affected:
    ALL
    

Problem conclusion

  • Segment trees updated to Update HI_Amount type in X223, X299 to
    remove partition, as this was affecting validation results if
    this subelement was null or blank, and restor# length to
    original 8
    
    Applies to:
    Healthcare Pack HIPAA 10.0.0, 10.0.3, 10.1.0, 10.2.0, 10.2.1
    
    Fixed in the next service packs and releases.
    
    To obtain the fix for this APAR:
    
    To see if the next service pack or product release is available,
    check the IBM Transformation Extender Downloads page:
    http://www.ibm.com/support/entry/portal/product/other_software/t
    ransformation_extender
    
    If the service pack or product release is available, download it
    from Fix Central:
    http://www.ibm.com/support/fixcentral/
    
    If the service pack or product release is not available and you
    require the APAR fix immediately, request a Limited Availability
    Interim Fix (LAIF) by opening a PMR:
    http://www.ibm.com/support/servicerequest/Home.action
    
    Prior to version 9.0.0, IBM Transformation Extender was called
    IBM WebSphere Transformation Extender.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH52657

  • Reported component name

    ITX

  • Reported component ID

    5724Q2300

  • Reported release

    A10

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2023-02-15

  • Closed date

    2023-06-09

  • Last modified date

    2023-06-09

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    ITX

  • Fixed component ID

    5724Q2300

Applicable component levels

[{"Business Unit":{"code":"BU029","label":"Software"},"Product":{"code":"SSVSD8","label":"Transformation Extender"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"A10"}]

Document Information

Modified date:
10 June 2023