APAR status
Closed as program error.
Error description
HIPAA Compliance Reports Failure when 837I 2300 HI*BE Segments have missing Value Code Amounts. When the Health Care Information Code - Value Information Segment (837I 2300 HI with HI01-01="BE") has missing Value Code Amounts (HInn-05), an incomplete data audit condition is triggered, the 999 does not include any element or sub-element level detail, and the 277CA Response status for the claim is not correct. Involves excess trailing delimiters and the "E15" data audit error code.
Local fix
ITXCQ - ITX00061773 LV / LV Circumvention: None
Problem summary
Users Affected: IBM Transformation Extender Pack for Healthcare HIPAA Problem Description: When 837P data has HI0n01=BE, and HI0n05 missing with all subelement delimiters present, data fails for entire segment and claim level rejection processing stopped. Platforms Affected: ALL
Problem conclusion
Segment trees updated to Update HI_Amount type in X223, X299 to remove partition, as this was affecting validation results if this subelement was null or blank, and restor# length to original 8 Applies to: Healthcare Pack HIPAA 10.0.0, 10.0.3, 10.1.0, 10.2.0, 10.2.1 Fixed in the next service packs and releases. To obtain the fix for this APAR: To see if the next service pack or product release is available, check the IBM Transformation Extender Downloads page: http://www.ibm.com/support/entry/portal/product/other_software/t ransformation_extender If the service pack or product release is available, download it from Fix Central: http://www.ibm.com/support/fixcentral/ If the service pack or product release is not available and you require the APAR fix immediately, request a Limited Availability Interim Fix (LAIF) by opening a PMR: http://www.ibm.com/support/servicerequest/Home.action Prior to version 9.0.0, IBM Transformation Extender was called IBM WebSphere Transformation Extender.
Temporary fix
Comments
APAR Information
APAR number
PH52657
Reported component name
ITX
Reported component ID
5724Q2300
Reported release
A10
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2023-02-15
Closed date
2023-06-09
Last modified date
2023-06-09
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
ITX
Fixed component ID
5724Q2300
Applicable component levels
[{"Business Unit":{"code":"BU029","label":"Software"},"Product":{"code":"SSVSD8","label":"Transformation Extender"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"A10"}]
Document Information
Modified date:
10 June 2023