A fix is available
APAR status
Closed as program error.
Error description
The LOGINFO Report is not honoring PARM=UPPER, which causes the report output to be mixed case.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of IMS Problem Investigator V2.5 * **************************************************************** * PROBLEM DESCRIPTION: LOGINFO Report does not honor * * PARM=UPPER * **************************************************************** LOGINFO Report does not honor PARM=UPPER
Problem conclusion
LOGINFO Report now honors PARM=UPPER; however, PARM=NOHEAD does not apply to the LOGINFO Report.
Temporary fix
Comments
APAR Information
APAR number
PH52433
Reported component name
IMS PROBLEM INV
Reported component ID
5655K5000
Reported release
250
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2023-02-07
Closed date
2023-02-22
Last modified date
2023-04-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI90662
Modules/Macros
ALZBATCH ALZLINFO
Fix information
Fixed component name
IMS PROBLEM INV
Fixed component ID
5655K5000
Applicable component levels
R250 PSY UI90662
UP23/03/09 P F303
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX8A4","label":"IMS Tools"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.5.0"}]
Document Information
Modified date:
03 April 2023