A fix is available
APAR status
Closed as program error.
Error description
ABENDC03 may occur in DRF XF job. This is because DRF XF does a GETMAIN with a DCB length of x'58' for the IMS command report DD RPTIMSCM.
Local fix
A workaround is to set the output of RPTIMSCM to SYSOUT.
Problem summary
**************************************************************** * USERS AFFECTED: All IMS Recovery Solution Pack for z/OS * * Version 2 Release 1 ( FMID=HAHM210 ) * * IMS Database Recovery Facility Extended * * Functions users. * **************************************************************** * PROBLEM DESCRIPTION: ABENDC03 may occur in DRF XF job. This * * is because DRF XF does a GETMAIN with a * * DCB length of x'58' for the Extended * * Functions. * **************************************************************** * RECOMMENDATION: INSTALL CORRECTIVE SERVICE FOR APAR/PTF * **************************************************************** If the DCB length of the extended function report is defined as x'58' in DRF XF, depending on the storage usage status of the entire system, if the report output destination is a data set, at CLOSE, an area with an address greater than the DCB offset x'58' and smaller than the DCB length may be broken, resulting in a SYSTEM ABEND.
Problem conclusion
DRF XF has been modified to specify the correct length when issuing GETMAIN for the DCB of the Extended Functions report DD.
Temporary fix
Comments
APAR Information
APAR number
PH52294
Reported component name
IMS RCVR SOLUTN
Reported component ID
5655V8600
Reported release
210
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2023-02-01
Closed date
2023-03-01
Last modified date
2023-04-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI90795
Modules/Macros
IROMDRV0
Fix information
Fixed component name
IMS RCVR SOLUTN
Fixed component ID
5655V8600
Applicable component levels
R210 PSY UI90795
UP23/03/03 P F303
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU011","label":"Systems - zSystems software"},"Product":{"code":"SG19M"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"2.1.0"}]
Document Information
Modified date: