Error description

  • BPA doesn't initialize dynamically obtained storage to store
    the value specified in the BPLTRACE started task parms. There-
    fore, if the IGVINITGETMAIN diag trap is specified, BPA will
    treat the STGINIT value set to that storage by the diag trap
    as the value specified for the BPLTRACE IGVINITGETMAIN started
    task parameters and an unexpected result can occur.  One known
    unexpected result is that the BPLTRACE started task issues a
    BPL278E message and terminates with user completion code 4081.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of IMS Buffer Pool Analyzer        *
    *                 for z/OS Version 1 Release 4 (FMID=H28A140)  *
    ****************************************************************
    * PROBLEM DESCRIPTION: When the z/OS DIAG TRAP IGVINITGETMAIN  *
    *                      is enabled, the BPLTRACE program,       *
    *                      which is a data gathering component,    *
    *                      will end unexpectedly.                  *
    ****************************************************************
    * RECOMMENDATION: Apply the maintenance for this APAR          *
    ****************************************************************
    BPLTRACE does not initialize dynamically obtained storage to
    store the value specified in the BPLTRACE started task
    parameters. So, if the z/OS DIAG TRAP IGVINITGETMAIN is
    enabled, BPLTRACE treats z/OS DIAG STGINIT value as the value
    specified for the BPLTRACE started task parameters, and an
    unexpected result will occur, such as outputting BPL278E
    message and terminating with ABEND U4081.
    

Problem conclusion

  • The following module have been changed to fix this problem:
    BPLTRACE.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH51817

  • Reported component name

    IMS BUFFER POOL

  • Reported component ID

    5697H7700

  • Reported release

    140

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2023-01-10

  • Closed date

    2023-02-10

  • Last modified date

    2023-03-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI90475

Modules/Macros

  • BPLTRACE
    

Fix information

  • Fixed component name

    IMS BUFFER POOL

  • Fixed component ID

    5697H7700

Applicable component levels

  • R140 PSY UI90475

       UP23/02/14 P F302

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCBTY3","label":"IMS Tools"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"1.4.0"}]

Document Information

Modified date:
01 March 2023