A fix is available
APAR status
Closed as program error.
Error description
A Db2 HPU step hangs after an ABENDSB37 has occured for a SORTIN dataset (allocated under a TnnnIN ddname), i.e. a dataset used when a sort process uses the SORTIN method as reported by messages such as INZX063 SORT ACTIVATED VIA SORTIN).
Local fix
None but the issue can be avoided by preventing the ABENDSB37 from occuring by either of te following ways: - changing the Db2 HPU settings to avoid the SORTIN method be used - ensuring the available storage space and the allocation parameters are suitable for the amount of data to be processed
Problem summary
**************************************************************** * USERS AFFECTED: Users of Db2 High Performance Unload * * for z/OS * **************************************************************** * PROBLEM DESCRIPTION: A Db2 HPU step hangs after an ABENDSB37 * * has occurred for a SORTIN dataset * * (allocated under a TnnnIN ddname), * * i.e. a dataset used when a sort process * * uses the SORTIN method as reported by * * messages such as INZX063 SORT ACTIVATED * * VIA SORTIN). * **************************************************************** * RECOMMENDATION: Apply the PTF * **************************************************************** Hanging situation after ABENDSB37 on SORTIN dataset
Problem conclusion
Code has been changed to fix this problem
Temporary fix
Comments
APAR Information
APAR number
PH51726
Reported component name
DB2 HI PERF UNL
Reported component ID
5697F4400
Reported release
510
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2023-01-05
Closed date
2023-02-13
Last modified date
2023-03-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
INZCRXSM INZCRXSQ INZUTILK
Fix information
Fixed component name
DB2 HI PERF UNL
Fixed component ID
5697F4400
Applicable component levels
R510 PSY UI90505
UP23/02/17 P F302
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.