Error description

  • HIPAA data fails on rule 59070 which enforces the balancing
    requirement that 2400 SV302 = SUM (2430 SVD02) + SUM (2430 CAS
    Adj's). Without the CTX segment that references the 2430 SVD
    segment, there is no indication that the error involves
    balancing instead of just a simple error with the contents of
    the 2400 SV302 element. If 0 is not a valid value for 2110
    CTX03, then the rules validation engine needs to be modified
    accordingly and return a non-zero segment position for the CTX
    segment whenever possible.
    
    The following 999 with CTX segment content shown below would let
    the user know that the 2400 SV302 error involves Other Payer
    Adjudication and specify the location of an SVD segment with the
    Other Payer's Payer-ID in 2430 SVD01.
    
    IK3*SV3*39*2400*8~
    IK4*2*782*I12*2~
    CTX*SITUATIONAL TRIGGER*SVD*41**2*782~
    
    The V9 compliance check 999 indicates the SVD segment caused the
     reported error for the 2400 SV302 element but the V10
    compliance check 999 indicates the error is limited to the 2400
    SV302 element content.
    

Local fix

  • ITXCQ - ITX00061679
    EY / EY
    Circumvention: None
    

Problem summary

  • Users Affected:
    IBM Transformation Extender Pack for Healthcare HIPAA
    
    Problem Description:
    HIPAA 999 Reporting Drops CTX Detail Returned by Rule Validation
    
    Platforms Affected:
    ALL
    

Problem conclusion

  • Multiple rule types in the hcsvu exit were updated to return the
     location of the first addend of the sum, so the CTX could be
    created with a non-zero segment location.
    
    Applies to:
    Healthcare Pack HIPAA  10.1.0, 10.2.0, 10.2.1
    
    Fixed in the next service packs and releases.
    
    To obtain the fix for this APAR:
    
    To see if the next service pack or product release is available,
    check the IBM Transformation Extender Downloads page:
    http://www.ibm.com/support/entry/portal/product/other_software/t
    ransformation_extender
    
    If the service pack or product release is available, download it
    from Fix Central:
    http://www.ibm.com/support/fixcentral/
    
    If the service pack or product release is not available and you
    require the APAR fix immediately, request a Limited Availability
    Interim Fix (LAIF) by opening a PMR:
    http://www.ibm.com/support/servicerequest/Home.action
    
    Prior to version 9.0.0, IBM Transformation Extender was called
    IBM WebSphere Transformation Extender.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH51479

  • Reported component name

    ITX

  • Reported component ID

    5724Q2300

  • Reported release

    A10

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2022-12-14

  • Closed date

    2023-03-10

  • Last modified date

    2023-06-05

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    ITX

  • Fixed component ID

    5724Q2300

Applicable component levels

[{"Business Unit":{"code":"BU029","label":"Software"},"Product":{"code":"SSVSD8","label":"Transformation Extender"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"A10"}]

Document Information

Modified date: