A fix is available
APAR status
Closed as program error.
Error description
User Response: No action is required. AUIL611I--RECON SCAN USING DATE/TIME: date/time AS THE PIVOT POINT. Explanation: The AUIL SLDS reader task will be considering SLDS data sets with a "Data Set End Time" (LOGDSETM) equal to or greater than the date/time PIVOT POINT for processing. SLDS data sets with a "Data Set End Time" prior to the the PIVOT point will not be read/processed. User Response: No action is required.
Local fix
n/a
Problem summary
SLDS Reader option IMSNAME_EQ_IMSSSID(Y) does not ignore extraneous checkpoints
Problem conclusion
These fix provides sensitivity to those incorrect checkpoints and will ignore them. Two new messages have also been added. AUIL610I--LAST SLDS READ WAS: data_set_name -DATE/TIME : data_set_time Explanation: The AUIL SLDS reader task has found a checkpoint SLDS. The DSN and "Data set Start Time" (LOGDSSTM) are displayed. User Response: No action is required. AUIL611I--RECON SCAN USING DATE/TIME: date/time AS THE PIVOT POINT. Explanation: The AUIL SLDS reader task will be considering SLDS data sets with a "Data Set End Time" (LOGDSETM) equal to or greater than the date/time PIVOT POINT for processing. SLDS data sets with a "Data Set End Time" prior to the PIVOT point will not be read/processed. User Response: No action is required.
Temporary fix
Comments
APAR Information
APAR number
PH50746
Reported component name
SEC GUAR STAP I
Reported component ID
5655STM00
Reported release
B30
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2022-11-08
Closed date
2022-12-12
Last modified date
2023-01-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI83683
Modules/Macros
AUIILINE AUIILINF AUIMGENU AUIRCNVS
Fix information
Fixed component name
SEC GUAR STAP I
Fixed component ID
5655STM00
Applicable component levels
RB30 PSY UI83683
UP22/12/14 P F212
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"IBM Security Guardium"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"B30"}]
Document Information
Modified date: