A fix is available
APAR status
Closed as program error.
Error description
The INVMAINT process will generate a S0C7 abend if the length of the INV$yy output data set name is exactly 44 characters. The INVMAINT process may experience a dynamic allocation error following a previous failed run.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All IBM Z Batch Resiliency (IZBR) users. * **************************************************************** * PROBLEM DESCRIPTION: 1. The RT/SMF Dispatcher INVMAINT sub * * task abends with S0C7 in module * * BRNVCI71. * * 2. The RT/SMF Dispatcher INVMAINT sub * * task reports a dynamic allocation * * error, BRNVC059 DYNALLOC ERROR * * - R15(04) S99ERR(0410). * **************************************************************** * RECOMMENDATION: Apply the provided PTF(s). * **************************************************************** 1. When an Inventory Maintenance report data set (INV$yy) is generated with a data set name exactly 44 characters long, this data set is not processed correctly by module BRNVCI71 causing a S0C7 abend. 2. The INVMAINT sub task does not correctly free resources following an out of space failure on the dynamically allocated report data set (INV$yy). This causes a dynamic allocation error on subsequent runs of the INVMAINT sub task.
Problem conclusion
1. Module BRNVCI71 has been changed to correctly process the Inventory Maintenance report data set when the generated data set name is exactly 44 characters. 2. The INVMAINT sub task has been changed to correctly free resources following an out of space failure on the dynamically allocated Inventory Maintenance report data set.
Temporary fix
Comments
APAR Information
APAR number
PH50630
Reported component name
IBM Z BATCH RES
Reported component ID
5698BR100
Reported release
120
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2022-11-02
Closed date
2022-11-15
Last modified date
2022-12-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI83300
Modules/Macros
BRNVC059 BRNVCI71 BRNVL020
Fix information
Fixed component name
IBM Z BATCH RES
Fixed component ID
5698BR100
Applicable component levels
R120 PSY UI83300
UP22/11/19 P F211
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"120"}]
Document Information
Modified date: