IBM Support

PH50528: NCPDP VALIDATION: QUESTION NUMBER/LETTER (378-4B) MISSING. AND FIELD 489-TE IS A MANDATORY FIELD, TRANSACTIONS ARE NOT FAILING

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

 

APAR status

  • Closed as program error.

Error description

  • Transformation Extender Pack for Healthcare V10.2.0
    
    378-4B - Required if Question Number/Letter Count (377-2Z) is
    greater than 0.  Files are passing compliance and failing in
    data translation.
    
    Field 489-TE is a mandatory field that can be repeated.
    Transactions are not failing compliance when this field is
    missing in any repeating group after the first occurrence.  This
    condition fails in the map with a transformation error.
    
    Examples:
    One occurrence of mandatory repeating fields 488-RE, 489-TE and
    448-ED, 489-TE is missing - Fails compliance correctly.
    
    If there are additional occurrences of mandatory repeating
    fields 488-RE, 489-TE and 448-ED, and 489-TE is missing - Does
    not fail compliance, fails in the map with a translation error.
    

Local fix

  • ITXCQ - ITX00061632
    CF / CF
    Circumvention: None
    

Problem summary

  • Users Affected:
    IBM Transformation Extender Pack for Healthcare NCPDP
    
    Problem Description:
    
    Question Number/Letter (378-4B) Missing. Java exit validation
    logic was incorrect for repeating groups.  This resulted in out
    of order fields or missing fields that are required if the
    repeat group exists not being reported.
    
    Platforms Affected:
    ALL
    

Problem conclusion

  • Updated ncpdp_jexit.js and segment_rules.json to properly report
     errors on missing or out of sequence fields in repeating
    groups.
    
    Applies to:
    
    Healthcare Pack NCPDP  10.1.0, 10.2.0
    
    Fixed in the next service packs and releases.
    
    To obtain the fix for this APAR:
    
    To see if the next service pack or product release is available,
    check the IBM Transformation Extender Downloads page:
    http://www.ibm.com/support/entry/portal/product/other_software/t
    ransformation_extender
    
    If the service pack or product release is available, download it
    from Fix Central:
    http://www.ibm.com/support/fixcentral/
    
    If the service pack or product release is not available and you
    require the APAR fix immediately, request a Limited Availability
    Interim Fix (LAIF) by opening a PMR:
    http://www.ibm.com/support/servicerequest/Home.action
    
    Prior to version 9.0.0, IBM Transformation Extender was called
    IBM WebSphere Transformation Extender.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH50528

  • Reported component name

    ITX

  • Reported component ID

    5724Q2300

  • Reported release

    A10

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2022-10-28

  • Closed date

    2023-03-10

  • Last modified date

    2023-04-10

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    ITX

  • Fixed component ID

    5724Q2300

Applicable component levels

[{"Business Unit":{"code":"BU029","label":"Software"},"Product":{"code":"SSVSD8","label":"Transformation Extender"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"A10"}]

Document Information

Modified date:
11 April 2023