A fix is available
APAR status
Closed as program error.
Error description
In IDz v15.0.5 User enabled AT-TLS encryption ran the IVP's, but the IVP Daemon is unsuccessful. Executing the IVP ISPF and PASSTICKET were successful. IVP DAEMON,XXXXXX, command entered Invoking fekfdivp by user id, XXXXXX Check attls policy:false,-1:-1:checkATTLS SIOCTTLSCTL ioctl error, rc -1, errno 1124(EDC8124I Socket not connected.), errno2 0x08 AT-TLS protection validation fails: -1:-1:checkATTLS SIOCTTLSCTL ioctl error, rc -1, errno 1124(EDC8124I Socket not con Workaround: None
Local fix
NA
Problem summary
**************************************************************** * USERS AFFECTED: 1. All users running Daemon Operator * * command IVP DAEMON * **************************************************************** * PROBLEM DESCRIPTION: 1. The gsk ssl client socket created * * by the tools is required to import * * the trusted server certificate in * * the connection with Daemon through * * AT-TLS layer in the test. Daemon * * non-SSL mode setting prevent the * * tool from configuring the client ssl * * socket properly, causing the failure * * of the test. * **************************************************************** 1. The client socket should be configured with gsk ssl and attached with the trusted server certificate when Daemon is on AT-TLS mode.
Problem conclusion
1. Have the client socket to detect AT-TLS mode of Daemon. Specify the key ring in daemon_keydb_file parameter for the tool to access and uses in ssl configuration of its client socket.
Temporary fix
Comments
APAR Information
APAR number
PH50480
Reported component name
Z/OS EXPLORER E
Reported component ID
5724T0723
Reported release
320
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2022-10-27
Closed date
2022-11-10
Last modified date
2022-12-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
PH50818
Modules/Macros
FEJENF70 FEJJCNFG FEJJJCL FEJJMON FEJTSO FEK1SMPE FEK2RCVE FEK3ALOC FEK4ZFS FEK5MKD FEK6DDEF FEK7APLY FEK8ACPT FEK@CERR FEK@CONE FEK@CONF FEK@CUST FEK@DEB FEK@DESC FEK@FLOW FEK@GEN FEK@GENW FEK@ISPF FEK@IVP FEK@IVPD FEK@IVPW FEK@JCN1 FEK@JCNE FEK@JESJ FEK@MAIN FEK@MIGO FEK@OPTE FEK@OPTG FEK@OPTN FEK@PRIM FEK@RSE1 FEK@RSEO FEK@STRT FEK@TAB1 FEK@TAB2 FEK@TAB3 FEK@WRK1 FEK@WRK2 FEK@WRK3 FEK@WRK4 FEK@WRK5 FEKAPPCC FEKAPPCL FEKAPPCX FEKATTR FEKDSI FEKEESX0 FEKFASIZ FEKFATT1 FEKFBLD FEKFCIPH FEKFCLIE FEKFCMOD FEKFCMPR FEKFCMSG FEKFCOMM FEKFCOPY FEKFCOR6 FEKFCORE FEKFDBG FEKFDBG6 FEKFDBGM FEKFDIR FEKFDIR6 FEKFDIVP FEKFDST0 FEKFDST1 FEKFDST2 FEKFENVF FEKFENVI FEKFENVP FEKFENVR FEKFENVS FEKFEPL FEKFERRF FEKFGDGE FEKFICUL FEKFISPF FEKFIVP0 FEKFIVPA FEKFIVPD FEKFIVPI FEKFIVPJ FEKFIVPT FEKFJESM FEKFJESU FEKFJLIC FEKFJSON FEKFJVM FEKFLATR FEKFLDSI FEKFLDSL FEKFLEOP FEKFLOGS FEKFLPTH FEKFMAI6 FEKFMAIN FEKFMINE FEKFMNTL FEKFNTCE FEKFOMVS FEKFPATT FEKFPLUG FEKFPTC FEKFRIVP FEKFRMSG FEKFRSES FEKFRSRV FEKFSCMD FEKFSEND FEKFSSL FEKFSTUP FEKFT000 FEKFT001 FEKFT002 FEKFT003 FEKFT004 FEKFT005 FEKFT006 FEKFT007 FEKFT008 FEKFT009 FEKFT010 FEKFT011 FEKFT012 FEKFT013 FEKFT014 FEKFT015 FEKFT016 FEKFT017 FEKFT018 FEKFT019 FEKFT020 FEKFT021 FEKFT022 FEKFT023 FEKFT024 FEKFT025 FEKFTIVP FEKFTSO FEKFUTIL FEKFVERS FEKFXITA FEKFXITL FEKFZOS FEKHCONF FEKHCUST FEKHDEB FEKHDESC FEKHFLOW FEKHGEN FEKHISPF FEKHIVP FEKHIVPD FEKHJESJ FEKHMAIN FEKHMIGO FEKHOPTE FEKHOPTN FEKHPRIM FEKHRSE1 FEKHRSEO FEKHSTRT FEKHTAB1 FEKHTAB2 FEKINIT FEKKEYS FEKLOCKA FEKLOGR FEKLOGS FEKM00 FEKM01 FEKM02 FEKMKDIR FEKMOUNT FEKMSGC FEKMSGS FEKRACF FEKRSED FEKSAPF FEKSAPPL FEKSBPX FEKSCLAS FEKSCLOG FEKSCMD FEKSCPYM FEKSCPYU FEKSDSN FEKSENV FEKSETUP FEKSISPF FEKSJCFG FEKSJCMD FEKSJMON FEKSLPA FEKSPROG FEKSPTKT FEKSRSED FEKSSERV FEKSSTC FEKSSU FEKSUSER FEKXCFGE FEKXCFGI FEKXCFGM FEKXCFGT FEKXMAIN FEKXML HUHFCOR6 HUHFCORE
Fix information
Fixed component name
EXP FOR Z/OS HO
Fixed component ID
5655EXP23
Applicable component levels
R320 PSY UI83251
UP22/11/22 P F211
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSBDYH","label":"IBM Explorer for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"320","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
01 December 2022