A fix is available
APAR status
Closed as program error.
Error description
All users are unable to successfully use the QCF ISPF UI after a QCFIN open error. This issue is kicked off by a user getting a RACF authorization violation. After this, other users (who have access) intermittently cannot use the ISPF UI QCF panels.
Local fix
Recycle the QCF Server. An indication that the defect has occurred is when the following two messages appear at the same time: IQC8001E UNABLE TO OPEN DATASET, DDNAME=QCFIN@02 BPE0040E DYN UNALLOC FAILED FOR PRINT@02, RC=00000004/00000420
Problem summary
**************************************************************** * USERS AFFECTED: All IBM IMS Queue Control Facility for z/OS * * Version 3 Release 2 (FMID=H0GN320) users. * **************************************************************** * PROBLEM DESCRIPTION: All users are unable to successfully * * use the QCF ISPF UI after a QCFIN open * * error. This issue is kicked off by a * * user getting a RACF authorization * * violation. After this, other users * * (who have access) intermittently * * cannot use the ISPF UI QCF panels. * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * **************************************************************** When using the ISPF UI and detecting an OPEN error for the QCFIN data set, it terminates without being closed the QCFPRINT data set and the UNALLOCTE processing for the QCFPRINT data set fails in error postprocessing. This leaves the QCFPRINT data set allocated to the QCF Server, and when another user uses the ISPF UI, DYNALLOC fails, and it cannot be used successfully.
Problem conclusion
QCF has been changed to close the QCFPRINT data set after detecting an OPEN error for the QCFIN data set.
Temporary fix
Comments
APAR Information
APAR number
PH50416
Reported component name
IMS QUEUE CNTL
Reported component ID
5697E9900
Reported release
320
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2022-10-25
Closed date
2022-12-05
Last modified date
2023-01-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI83574
Modules/Macros
IQCXCTRL
Fix information
Fixed component name
IMS QUEUE CNTL
Fixed component ID
5697E9900
Applicable component levels
R320 PSY UI83574
UP22/12/07 P F212
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.