Error description
Customer is attempting to process, while EXTRACTing a table, a relationship based on a DB2 foreign key definition. Optim detects a possible change to the FK definition based on the current TIMESTAMP value from SYSRELS and initiates an update of the FK's shadow copy in Optim's directory. The update attempt and the entire user-initiated process end with a System Error. An Internal System Error has Occurred on 2022-03-21 11:02 Relationship is empty DB2Rel=1215(NFM), Rel=11.7.0 Code=-1, AuxInfo= 01 FOPQKDAA 20180619 COPYSENT (001330) DS_ReplaceFK 02 FOPQRDAA 20210512 PH36824 (002643) dsCreShadowforCID 03 FOPQRDAA 20210512 PH36824 (002373) dsCmpRData Other failing scenarios may include Access Definition creation/Edit or Optim relationship listing.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All Optim users. * **************************************************************** * PROBLEM DESCRIPTION: Optim may abort processing with a * * System Error while processing * * relationships based on a DB2 foreign * * key. * **************************************************************** A coding error causes access to incorrect storage location and randomly detects a condition causing a System Error.
Problem conclusion
Optim processing will be corrected.
Temporary fix
Comments
APAR Information
APAR number
PH50343
Reported component name
OPTIM MOVE FOR
Reported component ID
5655V0700
Reported release
B70
Status
CLOSED PER
PE
NoPE
HIPER
YesHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2022-10-20
Closed date
2022-11-15
Last modified date
2022-12-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
FOP9APIM FOPCFPMN FOPCXLIB FOPHSTM FOPI0000 FOPI0001 FOPINS0 FOPINS2 FOPIX000 FOPK04 FOPMAIN FOPMAMAI FOPMARCN FOPMCMAI FOPMCOLA FOPMCOLP FOPMDPRC FOPMECMN FOPMMUNU FOPMMUTL FOPMSELM FOPOMN FOPRS10 FOPRS9 FOPTC710 FOPTC71Y FOPTC71Z FOPZFMMN
Fix information
Fixed component name
OPTIM MOVE FOR
Fixed component ID
5655V0700
Applicable component levels
RB70 PSY UI83295
UP22/11/17 P F211 ¢
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"B70"}]
Document Information
Modified date:
01 December 2022