A fix is available
APAR status
Closed as program error.
Error description
Stand-alone Recovery Sensor of STEPLIB requires all libraries to be APF-authorized, but it will terminate normally even if they are not. In this APAR, IROSENSR will be modified to check the APF status of STEPLIB.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All IMS Recovery Solution Pack for z/OS * * Version 2 Release 1 ( FMID=HAHM210 ) * * Stand-alone Recovery Sensor users. * **************************************************************** * PROBLEM DESCRIPTION: If STEPLIB of the Stand-alone Recovery * * Sensor is not APF-authorize, dynamic * * allocation of the RECON data sets using * * IMSDALIB DD cannot be performed and * * ABEND with S206. * **************************************************************** * RECOMMENDATION: INSTALL CORRECTIVE SERVICE FOR APAR/PTF * **************************************************************** The Recovery Sensor manual states that all libraries specified in the STEPLIB must be APF-registered, but the Recovery Sensor does not check the APF-authorization status of STEPLIB. Therefore, If any of the libraries concatenated to STEPLIB is not APF-registered, and STEPLIB is not APF-authorized, dynamic allocation of RECON data sets using IMSDALIB DD cannot be performed and S206 ABEND will occur. Recovery sensor should check the APF authorization status of STEPLIB at the start time.
Problem conclusion
The Recovery Sensor has been modified as follows: The Recovery Sensor checks the APF-authorization status of the STEPLIB using the TESTAUTH macro at the start time, and if it is not APF-authorized, it issues error message IRO4017A and terminates with return code 8.
Temporary fix
Comments
APAR Information
APAR number
PH49839
Reported component name
IMS RCVR SOLUTN
Reported component ID
5655V8600
Reported release
210
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2022-09-27
Closed date
2022-10-11
Last modified date
2022-11-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI82782
Modules/Macros
IROSENSR
SC19328306 |
Fix information
Fixed component name
IMS RCVR SOLUTN
Fixed component ID
5655V8600
Applicable component levels
R210 PSY UI82782
UP22/10/13 P F210
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"2.1.0"}]
Document Information
Modified date:
01 November 2022