Error description

  • DTP_ST_ALLOC_ENTRY is not being set correctly when a table fills
    up.
    The A17DTALE in DFHA17DS , is supposed to be the total amount of
    storage (KB) allocated for the record entry blocks for shared
    data tables .
    

Local fix

  • n/a
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All CICS users.                              *
    ****************************************************************
    * PROBLEM DESCRIPTION: Incorrect statistics reported for a     *
    *                      shared data table's "Entries storage in *
    *                      use".                                   *
    ****************************************************************
    A user maintained shared data table was written to until it was
    full. When the final frame within the Entry data space was
    allocated, logic in DFHDTDC initialised it to nulls with a MVCL.
    As this took the end address of the frame from 7FFF8000 to
    80000000, the MVCL set the top bit off, so resulting in an
    invalid end address of 00000000. This caused the POOLEND and
    POOLNEXT addresses within the table's cell pool header to be
    incorrectly set up, and hence the TP_ST_ALLOC_ENTRY statistics
    field incorrectly reporting nulls.
    

Problem conclusion

  • DFHDTDC has been changed to correctly set the final frame's end
    address value to 80000000.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH49836

  • Reported component name

    CICS TS Z/OS V5

  • Reported component ID

    5655Y0400

  • Reported release

    200

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2022-09-27

  • Closed date

    2022-11-02

  • Last modified date

    2022-12-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    PH49872 UI83095 UI83096

Modules/Macros

  • DFHDTDC
    

Fix information

  • Fixed component name

    CICS TS Z/OS V5

  • Fixed component ID

    5655Y0400

Applicable component levels

  • R200 PSY UI83096

       UP22/11/03 P F211

  • R300 PSY UI83095

       UP22/11/10 P F211

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGMGV","label":"CICS Transaction Server"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.5","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date:
01 December 2022