IBM Support

PH49834: SYSTEM ERROR DISPLAYING UNLOAD PARAMETERS PANEL IN COMPARE/EXTRACT/ARCHIVE

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Optim users defining an Archive/Extract/Compare process that
    will use an external unload program to retrieve the data rather
    than DB2 may experience a system error when requesting the
    'Specify Unload Program Parameters' panel be displayed:
    
      An Internal System Error has Occurred on 2022/09/27 10:54
    
    Error in Panel Input.  See Trace Records in Output Queue
    DB2Rel=1215(NFM), Rel=11.7.0
    Code=-1, AuxInfo=
    01  FOPEPANL 20220720 PH45127  (000569) PreScan
    02  FOPEPANL 20220720 PH45127  (000179) ProcessPanel
    03  FOPJPER  20220720 PH45127  (001339) PerformExtract
    04  FOPJEXT  20220720 PH45127  (001574) ProcessExtCmds
    05  FOPJEXT  20220720 PH45127  (000590) SetUpExtract
    06  FOPJINI  20220720 PH45127  (000576) StartJobSubmission
    07  FOPJINI  20220720 PH45127  (000587) StartJobSubmission
    08  FOPMCALL 20220720 PH45127  (001749) CallJSub
    09  FOPMMENU 20220720 PH45127  (001795) PromptDM
    10  FOPMMENU 20220720 PH45127  (000948) PromptMain
    11  FOPMMAIN 20220720 PH45127  (000998) Main
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Optim users selecting an external unload     *
    *                 utility to retrieve DB2 data during an       *
    *                 Archive/Compare/Extract process.             *
    ****************************************************************
    * PROBLEM DESCRIPTION: When the 'Specify Unload Program        *
    *                      Parameters' panel is to be displayed    *
    *                      from which the values to be passed to   *
    *                      the unload utility are defined, a       *
    *                      system error may ensue.                 *
    ****************************************************************
    * RECOMMENDATION: Apply the fix provided.                      *
    ****************************************************************
    Due to an error in the definition of the panel its
    display is prevented and the Optim session is
    terminated.
    

Problem conclusion

  • The error has been corrected.
    NOTE:
    As part of this correction all date and time values
    defined as criteria to pass to the unload utility
    MUST BE ENTERED IN ISO format regardless of the DB2
    subsystem date and time format settings.  If a 'local'
    format has been defined Optim will internally
    convert the ISO value for validation prior to generating
    the SYSIN data statements containing the parameters passed
    to the unload program when the JCL is submitted.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH49834

  • Reported component name

    OPTIM MOVE FOR

  • Reported component ID

    5655V0700

  • Reported release

    B70

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2022-09-27

  • Closed date

    2022-10-12

  • Last modified date

    2022-11-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI82819 PH50166

Modules/Macros

  • FOP9APIM FOPCFPMN FOPCXLIB FOPHSTM  FOPK06   FOPMAIN  FOPMCMAI
    FOPMCOLA FOPMCOLP FOPMDBMN FOPMDDDL FOPMDPRC FOPMDXTR FOPMECMN
    FOPMEMAI FOPMMCMR FOPMMJBS FOPMMUTL FOPOMN   FOPZFBMN FOPZFMMN
    

Fix information

  • Fixed component name

    OPTIM MOVE FOR

  • Fixed component ID

    5655V0700

Applicable component levels

  • RB70 PSY UI82819

       UP22/10/14 P F210

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.