IBM Support

PH49717: NEW DFHLG0803 MESSAGE INTRODUCED BY APAR PH39710 IS MISSING IN DFHMELGE IN CICS TS 6.1

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • APAR PH39710 introduced new DFHLG0803 message if a DFHLG0772 is
    issued for a 8,82D response from the z/OS Logger for DFHLOG or
    DFHSHUNT to explain why we have to terminate CICS region. In
    CICS TS 6.1 that message is missing which causes DFHME0108
    message be issued to indicate it cannot be found.
    

Local fix

  • N/A
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All CICS users.                              *
    ****************************************************************
    * PROBLEM DESCRIPTION: Message DFHLG0803 not found in module   *
    *                      DFHMET1E                                *
    ****************************************************************
    CICS issues a generic log failure message DFHLG0772 for an
    IXGLOGR return/reason codes of X'00000008', X'0000082D'
    (IxgRsnCodeExpiredStmToken). An additional informational message
    DFHLG0803 should be issued along with  DFHLG0772 to indicate
    that the z/OS logger has detected an expired stream token on an
    operation against a CICS system log logstream.
    However, an error message was issued indicating that DFHLG0803
    was not found in the module DFHMET1E.
    

Problem conclusion

  • The CICS Messages manual will be updated with the following
    new message:
    DFHLG0803 applid The z/OS logger has detected an expired stream
    token on an operation against a CICS system log logstream.
    Explanation: The z/OS logger has returned an
    IxgRsnCodeExpiredStmToken (0000082D) Reason Code to the CICS
    log manager. The token invalidation may be the result of an
    IXGLOGR region failure, for example.
    System action: CICS has to terminate and reconnect to the
    logstream during the next startup. An emergency restart will
    ensure any inflight work is backed out in a coordinated manner.
    User response: This is an informational message. Refer to
    earlier message DFHLG0772 for further details of the z/OS logger
    operation and logstream which returned the
    IxgRsnCodeExpiredStmToken Reason Code.
    Module: DFHL2HS2, DFHL2HS3, DFHL2HS4, DFHL2HS5, DFHL2HS6,
    DFHL2HS7, DFHL2HS8, DFHL2HS9, DFHL2HSF, DFHL2HSG, DFHL2HSJ,
    DFHL2HB
    XMEOUT parameters/Message inserts:
    1. applid
    Destination: Console
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH49717

  • Reported component name

    CICS TS Z/OS V6

  • Reported component ID

    5655YA100

  • Reported release

    400

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    YesSpecatt / CST / Xsystem

  • Submitted date

    2022-09-21

  • Closed date

    2022-12-02

  • Last modified date

    2023-01-06

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI83553

Modules/Macros

  • DFHMELGC DFHMELGE DFHMELGK
    

Fix information

  • Fixed component name

    CICS TS Z/OS V6

  • Fixed component ID

    5655YA100

Applicable component levels

  • R400 PSY UI83553

       UP22/12/03 P F212

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGMGV","label":"CICS Transaction Server"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"6.1","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date:
06 January 2023