IBM Support

PH49604: THE CDC Z/OS CLS TASK MAY BE BLOCKED ON ACCEPTING AN INCOMING CONNECTION AND STOPS THE ADDRESS SPACE SHUTDOWN TO PROCEED

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • If Communications Listener (CLS) task determines to accept an
    incoming connection but the connection is reset by remote side
    just before CDC actually accepts it, the accept process would be
     blocked until a new connection arrives. This would be an issue
    during CDC shutdown process, since no new connection arrives any
     more, CLS would be blocked on accept permanently and stops the
    CDC address space shutdown to proceed
    

Local fix

  • No
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of IIDR CDC for z/OS                   *
    ****************************************************************
    * PROBLEM DESCRIPTION: The CDC z/OS Communications Listener    *
    *                      (CLS) Task may be blocked permanently   *
    *                      on accepting an incoming connection and *
    *                      stops the address space shutdown to     *
    *                      proceed. Dump of the CDC address space  *
    *                      shows only MIT, OSC, CIT and CLS tasks  *
    *                      remaining, and the CLS task is stuck on *
    *                      accept() function.                      *
    ****************************************************************
    The CDC z/OS listener socket should be configured to use the
    non-blocking mode.
    

Problem conclusion

  • CDC z/OS listener socket has been changed from blocking mode to
    non-blocking mode.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH49604

  • Reported component name

    INFO SRVR CDC Z

  • Reported component ID

    5655U7600

  • Reported release

    A21

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2022-09-19

  • Closed date

    2022-09-29

  • Last modified date

    2022-11-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI82612

Modules/Macros

  • CHCMKCOM CHCMKTLS
    

Fix information

  • Fixed component name

    INFO SRVR CDC Z

  • Fixed component ID

    5655U7600

Applicable component levels

  • RA21 PSY UI82612

       UP22/10/11 P F210

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSTVMA","label":"InfoSphere Data Replication for DB2 for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"10.2.1","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date: