IBM Support

PH48586: OMPE - ABEND S0C4 DURING ACCOUNTING TOP PROCESSING

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • ABEND S0C4 during accounting TOP processing
    
    
    Accounting TOP processing does not set the Db2 version
    properly in ucbprint call, causing an 0C4 abend in FPEUCBPR
    print control module due to an invalid address.
    
    SYSTEM COMPLETION CODE=0C4  REASON CODE=00000010
      TIME=11.40.53 SEQ=23158  CPU=0000 ASID=0105
      PSW AT TIME OF ERROR  078D1000   9D13AFE2 ILC 4  INTC 10
      ACTIVE MODULE ADDRESS=00000000_1D000000  OFFSET=0013AFE2
      NAME=FPECMAIN
    

Local fix

  • na
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of OMPE Batch reporting ACCOUNTING     *
    ****************************************************************
    * PROBLEM DESCRIPTION: ABEND 0C4 DURING ACCOUNTING TRACE TOP   *
    *                      PROCESSING                              *
    ****************************************************************
    * RECOMMENDATION: APPLY PROVIDED PTF.                          *
    ****************************************************************
    ACCOUNTING TRACE PROCESSING ABENDS WITH 0c4-10 WHEN TOP SUBCOMM-
    AND OPTION IS USED UNDER ACCOUNTING TRACE DUE TO MISSING VERSION
    CHECK.
    

Problem conclusion

  • PROGRAM LOGIC AMENDED TO CORRECTLY RESOLVE THE ADDRESS.
    
    KEYWORDS:
    OMPE BATCH ACCOUNTING 0C4
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH48586

  • Reported component name

    OM XE DB2PE/PM

  • Reported component ID

    5655OPE00

  • Reported release

    550

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2022-08-10

  • Closed date

    2022-09-14

  • Last modified date

    2022-10-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • BPOMAB01 BPOMAXA0 DGOAFGEN DGOATRAC DGOATREC DGONF012 DGONF023
    DGONF030 DGONF050 DGONF060 DGONF070 DGONF100 DGONF130 DGONF140
    DGONF150 DGONF170 DGONF180 DGONF190 DGONF200 DGONF210 DGONF220
    DGONF230 DGONF240 DGONF250 DGONF260 DGONF270 DGONF280 DGONF320
    DGONF330 DGONF340 DGONF350 DGONF360 DGONF370 DGONF380 DGONF410
    DGONF500 DGONF8ST DGONF9ST DGONFIFA DGONFISE DGONFLST DGONFPAC
    DGONFWHD DGONFWP1 DGONFWP9 DGONFWPA DGONFXPK DGOVMSTR DGOW1FIL
    DGOWF106 DGOWF107 FPEVFLM  KDPHSTSX KDPJSTMS KDPJSTPS KDPJSTPW
    KDPMSMAN KDPPLEX  KDPPREG  KDPVRTMS KO2AHLR
    

Fix information

  • Fixed component name

    OM XE DB2PE/PM

  • Fixed component ID

    5655OPE00

Applicable component levels

  • R550 PSY UI82412

       UP22/09/17 P F209

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSZJXP","label":"DB2 Tools for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"550","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
03 October 2022