IBM Support

PH48392: ADD NEW COMPONENT IMS COMMON PAUSER

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as new function.

Error description

  • This APAR provides new component IMS Common Pauser for IMS Tools
    Common Services of IMS Tools Base. This component allows some
    product to enable BMP pause. Using BMP pause allows processes
    that cannot be performed when the active BMP is accessing the
    database to be performed by temporarily stopping the BMP.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of IBM IMS Tools Base for z/OS     *
    *                 Version 1 Release 7 (FMID: HAHN170) who use  *
    *                 the BMP pause feature of IMS Tools Common    *
    *                 Pauser through IMS Tools products.           *
    ****************************************************************
    * PROBLEM DESCRIPTION: This APAR includes the following        *
    *                      enhancements:                           *
    *                      - A new module of Common Services, the  *
    *                      IMS Tools Common Pauser is provided.    *
    ****************************************************************
    * RECOMMENDATION: Apply the maintenance for this APAR.         *
    ****************************************************************
    A new module of Common Services, the IMS Tools Common Pauser is
    provided.
    IMS Tools Common Pauser enables IMS Tools products to use the
    BMP pause feature.
    When you reorganize, or change the structure of, a database by
    using an IMS Tools product, you normally need to wait until
    all the BMPs that access that database are completed. However,
    by using the BMP pause feature, you can restructure a database
    without waiting for long-running BMPs to end; the BMP pause
    feature temporarily stops the BMPs that access the database.
    To use the BMP pause feature, a BMP application must be able
    to perform an extended restart.
    

Problem conclusion

Temporary fix

Comments

  • The following modules have been added:
    FOIUACBG FOIUALLO FOIUCATI FOIUCINI FOIUCONT FOIUDASP
    FOIUDAS1 FOIUDA15 FOIUDCBG FOIUDSCB FOIUDSIN FOIUDYTR
    FOIUGETM FOIUGSUB FOIUIMSV FOIUINIT FOIUINST FOIUJFCB
    FOIULCAT FOIULEV0 FOIULGDS FOIULOAD FOIULOCK FOIULQUE
    FOIUMDA0 FOIUMDST FOIUMDS1 FOIUMESG FOIUMSGL FOIUMSGT
    FOIUNAOB FOIUOF15 FOIUSCAT FOIUSQRD FOIUSQWR FOIUSRC0
    FOIUSUBS FOIUSUBT FOIUSVLS FOIUTRAC FOIUTSKL FOIUXCF
    FOIVFLG0 FOIVINS0 FOIVINS1 FOIVINS2 FOIVIVP0 FOIVOARC
    FOIVODBL FOIVORO1 FOIVORO2 FOIVORQB FOIVORQ0 FOIVORQ1
    FOIVORQ2 FOIVOSBT FOIVOSB0 FOIVPAB5 FOIVPAUP FOIVPA63
    FOIVPDB5 FOIVPDDA FOIVPDLH FOIVPDS1 FOIVPFA5 FOIVPFB5
    FOIVPFCM FOIVPFH5 FOIVPGQS FOIVPHKI FOIVPIX5 FOIVPLP5
    FOIVPMS  FOIVPNOM FOIVPNOP FOIVPOPA FOIVPOPL FOIVPOPR
    FOIVPOPS FOIVPPR0 FOIVPPR1 FOIVPRCC FOIVPRQ0 FOIVPRQ1
    FOIVPRQ2 FOIVPRRC FOIVPTSV FOIVPUPI FOIVPUPO FOIVPUP0
    FOIVPZGE
    
    The following macro have been added:
    FOIUSET
    
    The following ISPF panels have been added:
    HKTQPCA4
    
    The following ISPF panels have been modified:
    HKTQHCA4 HKTQHGLX HKTQPCA1 HKTQPCA2 HKTQPCA3 HKTQPGLX
    

APAR Information

  • APAR number

    PH48392

  • Reported component name

    IMS TOOLS BASE

  • Reported component ID

    5655V9300

  • Reported release

    170

  • Status

    CLOSED UR1

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    YesSpecatt / New Function / Xsystem

  • Submitted date

    2022-08-02

  • Closed date

    2022-12-21

  • Last modified date

    2023-01-10

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI83780

Modules/Macros

  • FOIUACBG FOIUALLO FOIUCATI FOIUCINI FOIUCONT FOIUDA15 FOIUDAS1
    FOIUDASP FOIUDCBG FOIUDSCB FOIUDSIN FOIUDYTR FOIUGETM FOIUGSUB
    FOIUIMSV FOIUINIT FOIUINST FOIUJFCB FOIULCAT FOIULEV0 FOIULGDS
    FOIULOAD FOIULOCK FOIULQUE FOIUMDA0 FOIUMDS1 FOIUMDST FOIUMESG
    FOIUMSGL FOIUMSGT FOIUNAOB FOIUOF15 FOIUSCAT FOIUSET  FOIUSQRD
    FOIUSQWR FOIUSRC0 FOIUSUBS FOIUSUBT FOIUSVLS FOIUTRAC FOIUTSKL
    FOIUXCF  FOIVACT1 FOIVACT2 FOIVCAP1 FOIVCAP2 FOIVCAP3 FOIVCNFG
    FOIVFLG0 FOIVINS0 FOIVINS1 FOIVINS2 FOIVISTA FOIVIVP0 FOIVIVP1
    FOIVOARC FOIVODBL FOIVORO1 FOIVORO2 FOIVORQ0 FOIVORQ1 FOIVORQ2
    FOIVORQB FOIVOSB0 FOIVOSBT FOIVPA63 FOIVPAB5 FOIVPAUP FOIVPDB5
    FOIVPDDA FOIVPDLH FOIVPDS1 FOIVPFA5 FOIVPFB5 FOIVPFCM FOIVPFH5
    FOIVPGQS FOIVPHKI FOIVPIX5 FOIVPLP5 FOIVPMS  FOIVPNOM FOIVPNOP
    FOIVPOPA FOIVPOPL FOIVPOPR FOIVPOPS FOIVPPR0 FOIVPPR1 FOIVPRCC
    FOIVPRQ0 FOIVPRQ1 FOIVPRQ2 FOIVPRRC FOIVPTSV FOIVPUP0 FOIVPUPI
    FOIVPUPO FOIVPZGE HKTQCPG1 HKTQHCA4 HKTQHGLX HKTQLINK HKTQOSG1
    HKTQPCA1 HKTQPCA2 HKTQPCA3 HKTQPCA4 HKTQPGLX HKTQSETV
    

Fix information

  • Fixed component name

    IMS TOOLS BASE

  • Fixed component ID

    5655V9300

Applicable component levels

  • R170 PSY UI83780

       UP23/01/03 P F212

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCJN3E","label":"IMS Tools"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"170"}]

Document Information

Modified date:
10 January 2023