A fix is available
APAR status
Closed as program error.
Error description
With the addition of APAR OA59874, new crypto processor types were added to the SMF 70 Subtype 2 fields. IZPCA does not support the additional new fields.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All IBM Z Decision Support and IBM Z * * Performance and Capacity Analytics users * * of the z/OS Performance Management (MVSPM) * * component, subcomponent 11 Cryptographic * * Statistics. * **************************************************************** * PROBLEM DESCRIPTION: OA59874 introduced support for * * Cryptographic and Express8S Hardware * * Security Module on the IBM z16 server * * which has not been added to the SMF * * record 70 subtype 2 record definition. * * This causes the Crypto Hardware Type * * on the MVSPM Crypto Overview Report to * * display as $UNKNOWN. * **************************************************************** * RECOMMENDATION: Apply the provided PTF(s). * **************************************************************** The SMF record 70 subtype 2 record definition is missing some Cryptographic processor subtypes.
Problem conclusion
Additional processor types configured as Crypto Express8S Coprocessor(CEX8C), Crypto Express8S Accelerator(CEX8A) and Crypto Express8S PKCS11 Coprocessor (CEX8P) for IBM z16 have been added to the SMF record 70 subtype 2 record definition.
Temporary fix
Comments
APAR Information
APAR number
PH48119
Reported component name
TDS FOR Z/OS
Reported component ID
569510100
Reported release
C01
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2022-07-20
Closed date
2022-07-28
Last modified date
2022-08-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI81677 UI81678 UI81679 UI81680
Modules/Macros
DRLRS070 DRLTMPCC
Fix information
Fixed component name
TDS FOR Z/OS
Fixed component ID
569510100
Applicable component levels
R901 PSY UI81677
UP22/07/30 P F207
R9A0 PSY UI81678
UP22/07/30 P F207
RC01 PSY UI81679
UP22/07/30 P F207
RCA0 PSY UI81680
UP22/07/30 P F207