A fix is available
APAR status
Closed as program error.
Error description
The number of intervals that can be processed is arbitrarily limited to 100,000
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of Db2 Query Monitor Intervals * **************************************************************** * PROBLEM DESCRIPTION: S0C4 processing INTV command with more * * than 100,000 intervals * **************************************************************** * RECOMMENDATION: Apply the PTF * **************************************************************** ISPF ABEND0C4 in CQM$INVA issuing INTERVAL command if current CQM INTERVAL number exceeds 100,000
Problem conclusion
Code was changed to allow processing of interval numbers greater than 100,000.
Temporary fix
Comments
APAR Information
APAR number
PH48012
Reported component name
DB2 QUERY MONIT
Reported component ID
5655E6701
Reported release
330
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2022-07-14
Closed date
2022-08-25
Last modified date
2022-09-09
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
CQM#BCMX CQM#COMX CQM$$CCQ CQM$INTV CQMMEMTX CQMMMETX
Fix information
Fixed component name
DB2 QUERY MONIT
Fixed component ID
5655E6701
Applicable component levels
R330 PSY UI82112
UP22/08/30 P F208
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSZJXP","label":"DB2 Tools for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.3.0","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
09 September 2022