IBM Support

PH47996: ENHANCEMENTS TO SUPPORT PASSING XID TO DB2, NEEDS A LARGE ENOUGHAREA OF STORAGE TO ACCOMMODATE THE XID BEING PASSED BACK BY RRS

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Support for passing XID to Db2 added at CICS TS 5.5 is not
    working as expected.
    

Local fix

  • no local fix
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All CICS Users.                              *
    ****************************************************************
    * PROBLEM DESCRIPTION: CICS-Db2 attach will query MVS RRS to   *
    *                      obtain an XID and may see an increase   *
    *                      in RRS CPU time.                        *
    ****************************************************************
    CICS-Db2 Attach will query MVS RRS to see if a unit of work was
    initiated from outside CICS and is being coordinated by MVS RRS
    to obtain an XID.
    You may seen an increase in RRS CPU time. This is because the
    ATRQUERY issued by CICS was sent to all systems in the sysplex
    regardless of their RRS logging group.
    

Problem conclusion

  • The ATRQUERY issued by CICS has been amended to remove the GNAME
    parameter so that it defaults to querying systems with the same
    RRS logging group as the current system.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH47996

  • Reported component name

    CICS TS Z/OS V6

  • Reported component ID

    5655YA100

  • Reported release

    400

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2022-07-14

  • Closed date

    2022-07-21

  • Last modified date

    2022-08-02

  • APAR is sysrouted FROM one or more of the following:

    PH39766

  • APAR is sysrouted TO one or more of the following:

    UI81588

Modules/Macros

  • DFHD2EX1
    

Fix information

  • Fixed component name

    CICS TS Z/OS V6

  • Fixed component ID

    5655YA100

Applicable component levels

  • R400 PSY UI81588

       UP22/07/22 P F207