A fix is available
APAR status
Closed as program error.
Error description
Customer is performing EXTRACT processing of related DB2 and LEGACY (IMS) tables. There are relationships defined between the DB2 tables and IMS LTs based on fields with UNSIGNED DECIMAL data. Optim selects SCAN as default method of following the relationships but customer decided to override the ACM and requested that ACM KEY be used instead. The forced use of KEY may lead to incorrect data, or no data at all, being extracted.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Optim users performing EXTRACT processing of * * LEGACY tables related to DB2 tables. * **************************************************************** * PROBLEM DESCRIPTION: Optim may return incorrect results. * **************************************************************** Optim is allowing for Access Method (ACM) override of KEY in scenarios where such override may cause incorrect results.
Problem conclusion
Optim processing will be corrected and ACM KEY override disabled while processing LEGACY tables related to DB2 tables and involving UNSIGNED DECIMAL data.
Temporary fix
Comments
APAR Information
APAR number
PH47886
Reported component name
OPTIM MOVE FOR
Reported component ID
5655V0700
Reported release
B70
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2022-07-13
Closed date
2022-08-08
Last modified date
2022-09-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
FOP1OSFN FOP9APIM FOPCFPMN FOPHSTM FOPK05 FOPMADDE FOPMAIN FOPMARCN FOPMCMAI FOPMDXTR FOPMECMN FOPMMCMR FOPMMJBS FOPMMUNU FOPMMUTL FOPMUXIM FOPOMN FOPRS10 FOPTGRPA FOPZMAIN
Fix information
Fixed component name
OPTIM MOVE FOR
Fixed component ID
5655V0700
Applicable component levels
RB70 PSY UI81862
UP22/08/16 P F208
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"B70"}]
Document Information
Modified date:
01 September 2022