A fix is available
APAR status
Closed as new function.
Error description
This APAR provides preconditioning code for new functions.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of IBM Tools Base for z/OS * * Version 1 Release 6 (FMID: HAHN160) who use * * the Autonomics Director and the IMS Tools * * Knowledge Base. * **************************************************************** * PROBLEM DESCRIPTION: IMS Tools Base 1.6 should not have * * access to the repositories of IMS Tools * * Base 1.7. * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR and * * restart Autonomics Director server. * **************************************************************** This enhancement prevents access to repositories of IMS Tools Base 1.7 from IMS Tools Base 1.6. The following enhancements are provided: 1. The Autonomics Director server abnormally terminates with U0700 and IAV0033E message if it accesses the incompatible repositories. 2. The IMS Tools Discovery utility abnormally terminates with U4075 and HKTD515E message if it accesses the incompatible repositories. 3. The HKTARCNI utility terminates with RC=12 if it accesses the incompatible repositories. 4. The Autonomics Director 1.6 ISPF interface prevents access to the Autonomics Director 1.7 server.
Problem conclusion
Temporary fix
Comments
APAR Information
APAR number
PH47848
Reported component name
IMS TOOLS BASE
Reported component ID
5655V9300
Reported release
160
Status
CLOSED UR1
PE
NoPE
HIPER
NoHIPER
Special Attention
YesSpecatt / New Function / Xsystem
Submitted date
2022-07-08
Closed date
2022-07-28
Last modified date
2022-08-19
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI81681
Modules/Macros
HKTALSR1 HKTALSR2 HKTARCNA HKTARCNI HKTDDSC0 IAVD0ENU IAVDSITK IAVTGSRV IAVTPRIM
SC19437202 | SC19437604 |
Fix information
Fixed component name
IMS TOOLS BASE
Fixed component ID
5655V9300
Applicable component levels
R160 PSY UI81681
UP22/07/29 P F207
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCJN3E","label":"IMS Tools"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"160"}]
Document Information
Modified date: