Error description
The CICS supplied STAT transaction produces online statistics reports. One of them is the Dispatcher TCB mode. A change in 6.1 made two fields' value incorrect in the report. This does not affect any statistics SMF records though. STAT Dispatcher TCB mode report has strange numbers.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All. * **************************************************************** * PROBLEM DESCRIPTION: Incorrect values for Accumulated CPU * * and SRB times reported by DFH0STAT. * **************************************************************** Running CICS transaction STAT, drives DFH0STAT(DFH0STSY) which links to DFH$STAS. A commarea is used but an incorrect declaration causes Dispatcher TCB Modes fields: Address Space Accumulated CPU Time and Address Space Accumulated SRB Time which are contained in the STAT report to both contain values that are incorrect.
Problem conclusion
DFH0STAT code has been modified to rectify the aforementioned problem.
Temporary fix
Comments
APAR Information
APAR number
PH47717
Reported component name
CICS TS Z/OS V6
Reported component ID
5655YA100
Reported release
400
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2022-07-04
Closed date
2022-11-09
Last modified date
2022-12-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI83194
Modules/Macros
DFH0STSY
Fix information
Fixed component name
CICS TS Z/OS V6
Fixed component ID
5655YA100
Applicable component levels
R401 PSY UI83194
UP22/11/10 P F211
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGMGV","label":"CICS Transaction Server"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"6.1","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
01 December 2022