A fix is available
APAR status
Closed as program error.
Error description
S0C4 ABEND issuing the CLEAR primary command in the 'Define Column Map' panel. CEE3204S The system detected a protection exception (System Completion Code=0C4). From entry point ProcessCMPrimaryCmds at statement 7156 at compile unit offset +0000FE1C at entry offset +0000FE1C at address 24A086A4. Abend 0C4000 hex occurred processing command 'DSN '. ***
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Optim users issuing the CLEAR primary * * command within the Column Map editor. * **************************************************************** * PROBLEM DESCRIPTION: Issuing the CLEAR primary command may * * result in an S0C4 ABEND: * * CEE3204S The system detected a * * protection exception (System Completion * * Code=0C4). * * From entry point ProcessCMPrimaryCmds * * at statement 7156 at compile unit * * offset +0000FE1C at entry offset * * +0000FE1C at address 24A086A4. * * Abend 0C4000 hex occurred processing * * command 'DSN ' * * *** * **************************************************************** * RECOMMENDATION: Apply the fix provided. * **************************************************************** Optim was using an incorrect counter when processing the columns within the editor to process the command.
Problem conclusion
The error has been corrected.
Temporary fix
Comments
APAR Information
APAR number
PH47655
Reported component name
OPTIM MOVE FOR
Reported component ID
5655V0700
Reported release
B70
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2022-06-30
Closed date
2022-07-21
Last modified date
2022-08-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
FOP00003 FOP00103 FOP00203 FOP00303 FOP00B FOP01B FOP05B FOP07B FOP08B FOP09B FOP0AB FOP0BB FOP0DAUE FOP0ITKA FOP1ODRV FOP1OSFN FOP1XTRN FOP3DTPR FOP4IPMN FOP4PEMN FOP4PMMN FOP4TRCE FOP9APIM FOP9GINF FOPCFPMN FOPCXLIB FOPHSTM FOPIO FOPK06 FOPMACAS FOPMADDE FOPMAFCN FOPMAIN FOPMAMAI FOPMARCN FOPMCBMN FOPMCDRT FOPMCENU FOPMCMAI FOPMCMMN FOPMCOFN FOPMCOLA FOPMCOLP FOPMDBMN FOPMDDDL FOPMDMAI FOPMDPRC FOPMDXTR FOPMECMN FOPMEMAI FOPMIXMM FOPMMCMN FOPMMCMR FOPMMJBS FOPMMUNU FOPMMUTL FOPMSELM FOPMSORT FOPMTMDB FOPMUXIM FOPODPP FOPOMN FOPRS10 FOPRS4 FOPRS5 FOPRS6 FOPRS7 FOPRS9 FOPTC710 FOPTC71V FOPTXPR3 FOPUBMC FOPUIAUL FOPUMCBT FOPUUNLD FOPVOU FOPZFBMN FOPZFMMN FOPZMAIN FOPZSUB
Fix information
Fixed component name
OPTIM MOVE FOR
Fixed component ID
5655V0700
Applicable component levels
RB70 PSY UI81610
UP22/07/23 P F207
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"B70"}]
Document Information
Modified date:
02 August 2022